AHMAD AGNI, . (2014) STUDI EKSPERIMENTAL PRESSURE DROP ALIRAN GELEMBUNG (AIR – UDARA) PADA PIPA BERULIR DALAM DENGAN KEMIRINGAN SUDUT 0O - 50O. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.
Text
STUDI EKSPERIMENTAL PRESSURE DROP ALIRAN GELEMBUNG.pdf Download (4MB) |
Abstract
Penelitian ini bertujuan untuk mencari pengaruh perubahan debit udara, debit air dan kemiringan pipa berulir dalam spesimen uji terhadap pressure drop pada aliran dua fasa ( air – udara) pada pola aliran gelembung dan untuk mengetahui distribusi gerakan gelembung pada pipa berulir dalam. Metode yang digunakan dalam penelitian ini adalah metode eksperimen laboratorium, yaitu untuk menentukan debit air, debit udara, kemiringan pipa, perbedaan tekanan dan distribusi gerakan gelembung dalam bentuk foto. Hasil penelitian laboratorium kemudian dilakukan perhitungan dan analisis untuk mengetahui pressure drop, hasil analisis pressure drop dari penelitian laboratorium selanjutnya dibandingkan dengan pressure drop berdasarkan analisis korelasi metode homogeneous . Hasil penelitian menunjukan semakin tinggi debit air, debit udara dan kemiringan pipa, distribusi gerakan gelembungnya semakin mengikuti bentuk ulir dalam pipa. Selain itu perubahan debit air ,debit udara dan kemiringan pipa berpengaruh terhadap pressure drop, di tunjukan pada pressure drop statis pada sudut 500, 6 LPM dan 20 cc/menit sebesar 14963.8 N/m2. ************ This study aimed to explore the effect of changes in the volume of air, water discharge and slope threaded pipe in the test specimen to the pressure drop in two-phase flow in the flow pattern of bubbles and bubble flow to look for movement on the threaded pipe, where the two-phase flow in this study on the use of water and air mixing. The method used in this study was a laboratory experimental method, which determines the value of the calculation, the types of materials used and make the pressure drop test equipment using U Tube. Then do the testing. The results showed higher water flow follows the movement of the bubble flow screw in the pipe where the water discharge and 4 LPM and 6 LPM. In addition, changes and variations in air discharge pipe slope will result in varying forms bubbles flow. In addition, the slope of the pipe also affects the pressure drop, show a decrease in static pressure at an angle of 500, 6 LPM and 20 cc / min of 14963.8 N/m2 and a decrease in pressure caused friction in the pipe threaded in the greater, where greatest friction is at an angle of 500, 6 LPM and 60 cc / min at 194.299 N/m2.
Item Type: | Thesis (Sarjana) |
---|---|
Additional Information: | 1). H. Wardoyo, S.T, M.T. ; 2). Ragil Sukarno, S.T, M.T. |
Subjects: | Teknologi dan Ilmu Terapan > Teknik Mesin, Mekanika Teknik |
Divisions: | FT > S1 Pendidikan Teknik Mesin |
Depositing User: | Rima Safitri . |
Date Deposited: | 13 Mar 2021 03:57 |
Last Modified: | 13 Mar 2021 03:57 |
URI: | http://repository.unj.ac.id/id/eprint/14831 |
Actions (login required)
View Item |