RIBKA ULI, . (2016) “PEMBUATAN SOFTWARE AKUISISI DAN ANALISA KALIBRASI SEISMOMETER SHORT-PRIODE MENGGUNAKAN MEJA GETAR VOLNA BERBASIS SOFTWARE BUILDER LABVIEW”. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.
Text
Skripsi Ribka Uli.pdf Download (2MB) |
Abstract
Keakuratan seismometer diakui bila nilai sensitivitasnya terselusur ke satuan internasional ataupun nasional, yaitu dengan menjalani kalibrasi. Adapun dalam penelitian ini kalibrasi dilakukan dengan meja getar volna. Dalam mengkalibrasi seismometer tersebut dibutuhkan software akuisisi dan analisa kalibrasi. Karena program akuisisi dan analisa kalibrasi yang ada saat ini seringkali menghadapi kendala dalam penyesuain antara kalibrator dengan seismometer, maka peneliti membuat program akuisisi dan analisa kalibrasi dengan berbasis software builder LabVIEW. Hasil kalibrasi yang diperoleh program buatan tersebut pada frekuensi 0,8Hz, 1Hz, 2Hz, dan 5Hz memiliki rata-rata selisih yang cukup kecil ketika dibandingkan dengan nilai sensitivitas seismometer yang telah terselusur sebelumnya yaitu sekitar 0,8 sampai 13%. Signal keluaran yang dihasilkan program buatan ini juga lebih smooth ketika dibandingkan dengan program terdahulu yang sudah ada. Hal ini membuktikan bahwa program akuisisi dan analisa kalibrasi berbasis software builder LabView ini sudah cukup tepat dan akurat untuk digunakan dalam mengkalibrasi seismometer pada meja getar volna. The accuracy of the seismometer is recognized when the value of the sensitivity banisters to national or international units, namely by undergoing calibration. As in this study calibration is done by vibrating table Volna. In the seismometer calibrate the required software calibration acquisition and analysis. Because the program acquisition and analysis of existing calibration often face constraints in adjusting the calibrator with a seismometer, the researchers made a program acquisition and analysis software-based calibration with LabVIEW builder. Calibration results obtained by these artificial programs on 0,8Hz frequency, 1Hz, 2Hz and 5Hz had an average difference is quite small when compared to the value of the sensitivity seismometers have previously banisters which is about 0.8 to 13%. Signal output generated artificial program is also more smooth when compared to the previous program that already exists. This proves that the program acquisition and analysis software-based calibration LabView builder is precise and accurate enough to use in calibrating seismometer on a vibrating table Volna.
Item Type: | Thesis (Sarjana) |
---|---|
Additional Information: | 1) Dr. Mutia Delina, M.Si 2) Benyamin Heryanto R, M.Si |
Subjects: | Sains > Fisika |
Divisions: | FMIPA > S1 Fisika |
Depositing User: | sawung yudo |
Date Deposited: | 14 Apr 2022 02:46 |
Last Modified: | 14 Apr 2022 02:46 |
URI: | http://repository.unj.ac.id/id/eprint/26564 |
Actions (login required)
View Item |