MUSTOPA, . (2017) EVALUASI PENERAPAN SISTEM PROTEKSI DAN KESELAMATAN KEBAKARAN MENGGUNAKAN SOFTWARE CFSES (COMPUTERIZED FIRE SAFETY EVALUATION SYSTEM) PADA GEDUNG PASAR PRAMUKA. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.
Text
SKRIPSI FULL.pdf Download (3MB) |
Abstract
Penelitian ini bertujuan untuk mengevaluasi sistem proteksi kebakaran di gedung Pasar Pramuka. Metode dalam penelitian ini adalah dengan menggunakan desain deskriptif dengan pendekatan semi kuantitatif yang bersifat observasional dan dibantu dengan software Computerized Fire Safety Evaluation System (CFSES) yang mengukur 12 parameter keselamatan yang mengacu pada NFPA 101A Guide on Alternative Approaches to Life Safety. Kedua belas parameter tersebut adalah kontruksi gedung, segregasi bahaya, bukaan vertikal, sprinkler, sistem alarm kebakaran, pendeteksi asap, barang properti, pengendali asap, akses keluar, jalur evakuasi, kompartemenisasi dan pelatihan tanggap darurat. Hasil penelitian menunjukkan bahwa gedung Pasar Pramuka secara keseluruhan belum memenuhi persyaratan minimal yang ditetapkan oleh NFPA 101A melalui software CFSES. Variabel kontrol penyebaran api mendapatkan nilai -15.5 dari 2 yang dibutuhkan, untuk variabel kedua yaitu jalan keluar nilai yang didapatkan - 25 dari 0 yang dibutuhkan kemudian untuk penilaian keselamatan kebakaran umum mendapatkan nilai -27 dari 0 yang dibutuhkan. Berdasarkan hasil evaluasi tersebut menunjukkan bahwa penerapan sistem proteksi kebakaran di gedung Pasar Pramuka belum ada yang memenuhi persyaratan keselamatan minimum, pada akhirnya rekomendasi diberikan untuk perbaikan sistem proteksi dan keselamatan kebakaran. This study aims to evaluate the protection of life tools in Pasar Pramuka. The method in this study is descriptive design with semi quantitative approachment that is observasional and helped by software Computerized Fire Safety Evaluation System (CFSES), measures 12 parameter of safety refer to NFPA 101A Guide on Alternative Approaches to Life Safety. The twelfth was construction, segregation of hazard, vertical openings, sprinklers, fire alarm system, smoke detection, smoke control, interior finish, exit access, exit system, corridor/room separation and occupancy emergency program. Overall, the result showed that the building of Pasar Pramuka does not fulfill the minimal requirement yet that is decided by NFPA 101A. the variable of fire control receives -15,5 from 2 that needed, for the second variable, the number receives - 25 from 0, and for the number of the general safety shows -27 from 0. Based on the evaluation showing that adoption of protection system fire at Pasar Pramuka scout yet no one is servicing minimum safety requirements, in the ends recommendations given to improvements to systems protection and fire safety.
Item Type: | Thesis (Sarjana) |
---|---|
Additional Information: | 1) Aam Aminingsih J, S.T., M.T 2) Triyono, S.T., M.Eng |
Subjects: | Teknologi dan Ilmu Terapan > Teknik Mesin, Mekanika Teknik |
Divisions: | FT > S1 Pendidikan Teknik Mesin |
Depositing User: | sawung yudo |
Date Deposited: | 24 May 2022 11:20 |
Last Modified: | 24 May 2022 11:20 |
URI: | http://repository.unj.ac.id/id/eprint/28932 |
Actions (login required)
View Item |