PERENCANAAN INSTALASI HIDRAN PILLAR MENURUT NFPA 14 PADA KANTOR SALES AREA MANAGER PT. XYZ

MUHAMMAD AMMAR ZAHRAN, . (2023) PERENCANAAN INSTALASI HIDRAN PILLAR MENURUT NFPA 14 PADA KANTOR SALES AREA MANAGER PT. XYZ. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.

[img] Text
COVER.pdf

Download (1MB)
[img] Text
BAB 1.pdf.pdf

Download (77kB)
[img] Text
BAB 2.pdf.pdf
Restricted to Registered users only

Download (253kB) | Request a copy
[img] Text
BAB 3.pdf.pdf
Restricted to Registered users only

Download (274kB) | Request a copy
[img] Text
BAB 4.pdf.pdf
Restricted to Registered users only

Download (575kB) | Request a copy
[img] Text
BAB 5.pdf.pdf
Restricted to Registered users only

Download (333kB) | Request a copy
[img] Text
DAFTAR PUSTAKA.pdf.pdf

Download (277kB)
[img] Text
LAMPIRAN.pdf.pdf
Restricted to Registered users only

Download (742kB) | Request a copy

Abstract

Kantor Sales Area Manager Bandung yang berlokasi di Kota Bandung, merupakan salah satu lokasi kerja yang mencakup wilayah kerja Bandung dan sekitarnya. Kantor Area Penjualan ini dibangun pada tahun 90-an, namun awalnya difungsikan sebagai kantor TNI. Pada tahun 2017 kantor baru dipindahkan ke PT. XYZ. Namun, saat saya melakukan observasi lapangan. Kondisi proteksi kebakaran yang dipasang di gedung hanya Alat Pemadam Api Ringan. Padahal SNI dan NFPA menjelaskan bahwa bangunan dengan luas lebih dari 500 m2 wajib memiliki instalasi hydrant pillar, sedangkan sales office seluas 1.827 m2 hanya memiliki proteksi kebakaran aktif berupa Alat Pemadam Api Ringan atau APAR. Oleh karena itu, laporan ini berisi tentang perencanaan dan analisis sistem hydrant pillar dan kebutuhan air untuk pemadaman hydrant yang digunakan di Gedung Sales Area Manager Office yang berlokasi di kota Bandung. Dengan perencanaan yang mengacu pada standar NFPA 14, penelitian ini dilakukan dengan observasi di Kantor Pemasaran PT. XYZ yang berlokasi di Kota Bandung pada bulan April-Maret 2022. Pengolahan data observasi dilakukan di Prodi Teknik Keselamatan Kebakaran Fakultas Teknik Universitas Negeri Jakarta pada bulan Juni-Agustus 2022. Dari hasil perancangan telah dilakukan pemasangan hidran pilar, dapat disimpulkan bahwa kapasitas media pemadam yang dibutuhkan untuk mengatasi kebakaran di gedung manajemen area penjualan adalah 85.171 liter untuk air. Berdasarkan NFPA 14 untuk gedung manajemen area penjualan, jumlah pilar yang dibutuhkan untuk melindungi gedung dari bahaya kebakaran adalah 5 buah. Daya pompa yang dibutuhkan untuk pemasangan hydrant pillar adalah 12,54 hp. Instalasi pipa yang digunakan berada di atas tanah dan mengelilingi bangunan. *** The Sales Area Manager Bandung office, which is located in the city of Bandung, is one of the work locations that cover the working area of Bandung and its surroundings. This Sales Area Office was built in the 90s, but originally functioned as a TNI office. In 2017 the new office was moved to PT. XYZ. However, when I made field observations. The fire protection conditions installed in the building are only Light Fire Extinguishers. Even though SNI and NFPA explain that a building with an area of more than 500 m2 must have a hydrant pillar installation, while a sales office with an area of 1,827 m2 only has active fire protection in the form of a Light Fire Extinguisher or APAR. Therefore, this report contains planning and analysis of the pillar hydrant system and water requirements for extinguishing the hydrant used in the Sales Area Manager Office Building located in the city of Bandung. With planning referring to the NFPA 14 standard, this research was conducted by observing the Marketing Office of PT. XYZ which is located in Bandung City in April-March 2022. Observation data processing was carried out at the Fire Safety Engineering Study Program, Faculty of Engineering, Jakarta State University in June-August 2022. From the design results, pillar hydrants have been installed, it can be written that the capacity of the extinguishing media used needed to overcome the fire in the sales area management building is 85,171 liters of water. Based on NFPA 14 for building sales area management, the number of pillars needed to protect the building from fire hazards is 5 pieces. The pump power required for the installation of a hydrant pillar is 12.54 hp. Installation of pipes used above the ground and around the building.

Item Type: Thesis (Sarjana)
Additional Information: 1). Catur Setyawan Kusumohadi, M.T., Ph.D ; 2). Pratomo Setyadi, S.T., M.t
Subjects: Teknologi dan Ilmu Terapan > Teknik Mesin, Mekanika Teknik
Divisions: FT > S1 Rekayasa Keselamatan Kebakaran
Depositing User: Users 16989 not found.
Date Deposited: 23 Feb 2023 04:06
Last Modified: 23 Feb 2023 04:06
URI: http://repository.unj.ac.id/id/eprint/37006

Actions (login required)

View Item View Item