HARMONISA ARUS DAN TEGANGAN LISTRIK DI GEDUNG UNIVERSITY TRAINING CENTER (UTC) UNIVERSITAS NEGERI JAKARTA

MUHAMAD AKMALUDDIN HADI, . (2023) HARMONISA ARUS DAN TEGANGAN LISTRIK DI GEDUNG UNIVERSITY TRAINING CENTER (UTC) UNIVERSITAS NEGERI JAKARTA. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.

[img] Text
COVER.pdf

Download (1MB)
[img] Text
BAB 1.pdf

Download (131kB)
[img] Text
BAB 2.pdf
Restricted to Registered users only

Download (474kB) | Request a copy
[img] Text
BAB 3.pdf
Restricted to Registered users only

Download (229kB) | Request a copy
[img] Text
BAB 4.pdf
Restricted to Registered users only

Download (553kB) | Request a copy
[img] Text
BAB 5.pdf
Restricted to Registered users only

Download (121kB) | Request a copy
[img] Text
DAFTAR PUSTAKA.pdf

Download (122kB)
[img] Text
LAMPIRAN.pdf
Restricted to Registered users only

Download (1MB) | Request a copy

Abstract

Beban non linear adalah beban yang hubungan antara tegangan yang diberikan tidak linear dengan arus yang dihasilkan. Pengaplikasian beban non linear dapat menyebabkan gangguan harmonisa. Penyesuaian tingkat harmonisa telah diatur berdasarkan suatu standar yang berlaku. Pada gedung UTC – UNJ terdapat sejumlah peralatan elektronik seperti komputer, televisi, AC dan peralatan elektronik lainnya yang itu merupakan beban non linear serta terjadi kenaikan pada biaya pembayaran listrik gedung UTC – UNJ. Tujuan dari penelitian ini adalah untuk mengetahui nilai harmonisa arus dan tegangan listrik pada sistem tenaga listrik Gedung University Training Center UNJ dan Menentukan kandungan harmonisa arus dan tegangan listrik di Gedung University Training Center UNJ sesuai standard IEEE 519 – 1992. Metode yang digunakan dalam penelitian ini adalah kuantitatif dengan menggunakan pendekatan deskriptif. Teknik pengambilan data menggunakan studi literatur, observasi, dan pengukuran langsung di Gedung University Training Center Universias Negeri Jakarta menggunakan alat ukur Power Quality Analyzer (PQA) HIOKI PW3198. Analisis data yang digunakan adalah analisis kuantitatif. Pembahasan dan analisis nilai harmonisa adalah dengan mengambil nilai rata – rata tertinggi THDv dan THDi per fasa pada gedung lewat pengukuran 3 hari (26 – 28 Juli 2023) berturut – turut selama 24 Jam. Hasil analisis selanjutnya akan disandingkan dengan standard yang berlaku (mengacu pada Standard IEEE 519:1992), hal ini dilakukan sebagai bentuk pendeskripsian kandungan harmonisa yang terjadi di sistem tenaga listrik gedung University Training Center UNJ. Kesimpulan yang diperoleh adalah pada Gedung UTC – UNJ nilai THDv rata – rata pada setiap fasa adalah 1,53% pada fasa R, 1,66% pada fasa S dan 1,51% pada fasa T. Nilai persentaseTHDv masih memenuhi standar karena masih dalam batas standar yang diizinkan yaitu 5%. Sedangkan nilai THDi rata – rata pada setiap fasa adalah 53,83% pada fasa R, 46,11% pada fasa S dan 44,76% pada fasa T. Nilai Persentae THDi sudah tidak memenuhi standar karena melebihi batas standard yang diizinkan yaitu 20%. ***** Non-linear load is a load whose relationship between the applied voltage is not linear with the generated current. The application of non-linear loads can cause harmonic interference. Harmonic level adjustment has been regulated based on an applicable standard. In the UTC - UNJ building there are a number of electronic equipment such as computers, televisions, air conditioners and other electronic equipment which are non-linear loads and there is an increase in the cost of electricity payments for the UTC - UNJ building. The purpose of this study is to determine the harmonic value of current and voltage in the electrical power system of the University Training Center UNJ building and determine the harmonic content of current and voltage in the University Training Center UNJ building according to IEEE 519 - 1992 standard. The method used in this research is quantitative using a descriptive approach. Data collection techniques using literature studies, observations, and direct measurements at the University Training Center Building, State University of Jakarta using the HIOKI PW3198 Power Quality Analyzer (PQA) measuring instrument. The data analysis used is quantitative analysis. The discussion and analysis of harmonic values is by taking the highest average value of THDv and THDi per phase in the building through 3 days of measurement (July 26-28, 2023) consecutively for 24 hours. The analysis results will then be compared with the applicable standards (referring to Standard IEEE 519: 1992), this is done as a form of describing the harmonic content that occurs in the electrical power system of the University Training Center UNJ building. The conclusion obtained is that in the UTC - UNJ Building, the average THDv value in each phase is 1.53% in phase R, 1.66% in phase S and 1.51% in phase T. The percentage value of THDv still meets the standard because it is still within the permissible standard limit of 5%. While the average THDi value in each phase is 53.83% in phase R, 46.11% in phase S and 44.76% in phase T. The THDi Percentage value does not meet the standard because it exceeds the permitted standard limit of 20%.

Item Type: Thesis (Sarjana)
Additional Information: 1). Massus Subekkti, S.Pd., M.T. ; 2). Imam Arif Rahardjo, M.T.
Subjects: Teknologi dan Ilmu Terapan > Teknik Energi > Energi Listrik
Teknologi dan Ilmu Terapan > Teknik Energi
Divisions: FT > S1 Pendidikan Teknik Elektro
Depositing User: Users 19014 not found.
Date Deposited: 28 Aug 2023 02:28
Last Modified: 28 Aug 2023 02:28
URI: http://repository.unj.ac.id/id/eprint/39833

Actions (login required)

View Item View Item