PROTOTIPE SISTEM PENDETEKSI, PENANGGULANGAN, DAN MONITORING KEBAKARAN BERBASIS PLC S7-1200 SIEMENS TIA PORTAL

RIZKY FAJAR WIRATAMA, . (2023) PROTOTIPE SISTEM PENDETEKSI, PENANGGULANGAN, DAN MONITORING KEBAKARAN BERBASIS PLC S7-1200 SIEMENS TIA PORTAL. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.

[img] Text
COVER.pdf

Download (1MB)
[img] Text
BAB 1.pdf

Download (131kB)
[img] Text
BAB 2.pdf
Restricted to Registered users only

Download (778kB) | Request a copy
[img] Text
BAB 3.pdf
Restricted to Registered users only

Download (882kB) | Request a copy
[img] Text
BAB 4.pdf
Restricted to Registered users only

Download (568kB) | Request a copy
[img] Text
BAB 5.pdf
Restricted to Registered users only

Download (123kB) | Request a copy
[img] Text
DAFTAR PUSTAKA.pdf

Download (121kB)
[img] Text
LAMPIRAN.pdf
Restricted to Registered users only

Download (2MB) | Request a copy

Abstract

Penelitian ini bertujuan untuk membuat sebuah prototipe sistem pendeteksi,penanggulangan, dan monitoring kebakaran berbasis PLC S7-1200 Siemens TIA Portal, dimana pendeteksian potensi kebakaran berdasarkan adanya asap dan tinggi suhu dari prototipe ruangan. Penelitian dilakukan berdasarkan metode penelitian dan pengembangan. Dimulai dengan perencanaan desain berdasarkan masalah yang ditemukan, lalu membuat elektrikal diagram berdasarkan PLC S7-1200 Siemens, merancang program ladder, membuat prototipe alat dan mengunduh program kedalam PLC melalui perangkat lunak TIA Portal. Pengujian dilakukan pada perangkat keras dan perangkat lunak, hasil pengujian kemudian dianalisis berdasarkan kriteria dari hardware dan software yang digunakan. Penelitian menggunakan sensor RTD sebagai sensor suhu dan sensor Photoelectric sebagai sensor asap. Dari hasil pengujian perangkat keras, kecepatan sensor dalam mendeteksi kebakaran berdasarkan konsentrasi asap hasil pembakaran dan tinggi suhu dalam ruangan simulasi. Sensitivitas sensor RTD tergantung dari seberapa sumber gangguan yang digunakan. Sedangkan hasil pengujian perangkat lunak, program dapat merespon sinyal masukan dengan baik dan dapat memproses sesuai tujuan. Prototipe alat dapat bekerja dengan bagik dan sesuai dengan program yang dibuat. ***** This research aims to create a prototype system for detecting, controlling and monitoring fires based on the Siemens TIA Portal PLC S7-1200, where potential fire detection is based on the presence of smoke and high temperature from the prototype room. The research was conducted based on research and development methods. Starting with design planning based on the problems found, then making electrical diagrams based on the Siemens S7-1200 PLC, designing the ladder program, making tool prototypes and downloading the program into the PLC via the TIA Portal software. Testing was carried out on hardware and software, the test results were then analyzed based on the criteria of the hardware and software used. This research uses RTD sensors as temperature sensors and photoelectric sensors as smoke sensors.From the results of hardware testing, the speed of the sensor in detecting fires is based on the concentration of smoke from combustion and the high temperature in the simulated room. The sensitivity of the RTD sensor depends on the noise source used. While the results of software testing, the program can respond well to input signals and can process according to its purpose. The tool prototype can work well and according to the program created

Item Type: Thesis (Sarjana)
Additional Information: 1). Moch. Djaohar, M.Sc. ; 2). Drs. Readysal Monantun, M.Pd.
Subjects: Teknologi dan Ilmu Terapan > Teknik Energi > Energi Listrik
Teknologi dan Ilmu Terapan > Teknologi (umum)
Teknologi dan Ilmu Terapan > Teknik Elektronika
Teknologi dan Ilmu Terapan > Teknik Komputer
Divisions: FT > S1 Pendidikan Teknik Elektro
Depositing User: Users 19030 not found.
Date Deposited: 28 Aug 2023 06:18
Last Modified: 28 Aug 2023 06:18
URI: http://repository.unj.ac.id/id/eprint/39919

Actions (login required)

View Item View Item