EVALUASI KESESUAIAN INSTALASI LISTIK RUMAH TINGGAL DIATAS 15 TAHUN BERDASARKAN PUIL 2011 ( Studi Kasus Pada RT 009 dan 010 RW 05 Kelurahan Pisangan Timur Kecamatan Pulo Gadung )”

APRIANI HAZIZAH PUTRI, . (2024) EVALUASI KESESUAIAN INSTALASI LISTIK RUMAH TINGGAL DIATAS 15 TAHUN BERDASARKAN PUIL 2011 ( Studi Kasus Pada RT 009 dan 010 RW 05 Kelurahan Pisangan Timur Kecamatan Pulo Gadung )”. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.

[img] Text
COVER.pdf

Download (1MB)
[img] Text
BAB I.pdf

Download (176kB)
[img] Text
BAB II.pdf
Restricted to Registered users only

Download (451kB) | Request a copy
[img] Text
BAB III.pdf
Restricted to Registered users only

Download (414kB) | Request a copy
[img] Text
BAB IV.pdf
Restricted to Registered users only

Download (1MB) | Request a copy
[img] Text
BAB V.pdf
Restricted to Registered users only

Download (131kB) | Request a copy
[img] Text
DAFTAR PUSTAKA.pdf

Download (181kB)
[img] Text
LAMPIRAN.pdf
Restricted to Registered users only

Download (1MB) | Request a copy

Abstract

Penelitian ini bertujuan untuk mengetahui tingkat kesesuaian instalasi listrik rumah tinggal berumur di atas 15 Tahun berdasarkan PUIL 2011 di RT 009 dan 010 RW 05 Kelurahan Pisangan Timur Kecamatan Pulo Gadung. Berdasarkan kondisi perlengkapan listrik yaitu, PHBK, armatur pencahayaan dan fitting lampu, kotak kontak, penghantar, Miniature Circuit Breaker, sakelar, dan instalasi grounding. Metode yang digunakan dalam penelitian ini adalah metode deskriptif kuantitatif. Dengan cara mengobservasi setiap rumah dengan 7 aspek yang akan diteliti. Teknik analisis data yang digunakan yaitu dengan menggunakan statistik deskriptif. Yaitu peneliti menganalisis data dengan melukiskan, menunjukan atau meringkaskan data dengan cara yang bermakna, sehingga suatu pola akan muncul dari data yang telah dijaring. Hasil penelitian menunjukan bahwa rumah yang memiliki instalasi listrik sesuai dengan standar PUIL 2011 tiap item yaitu pada kategori sangat baik dengan persentase 100% didapat pada Sakelar dan MCB, 86% pada Armatur Pencahayaan dan Fitting Lampu. Pada kategori kurang baik dengan persentase 50% didapat pada penghantar. Pada kategori tidak baik dengan persentase 34% pada kotak kontak, 44% didapat pada PHBK, 10% didapat pada instalasi grounding. Kata kunci: Instalasi Listrik, PUIL 2011, Rumah Tinggal. ***** This study aims to determine the level of suitability of residential electrical installations over 15 years old based on PUIL 2011 in RT 009 and 010 RW 05 East Pisangan Village, Pulo Gadung District. Based on the condition of electrical equipment, namely, PHBK, lighting armature and light fittings, contact boxes, conductors, Miniature Circuit Breakers, switches, and grounding installations. The method used in this study is quantitative descriptive method. By observing each house with 7 aspects to be studied. The data analysis technique used is to use descriptive statistics. That is, researchers analyze data by describing, showing or summarizing data in a meaningful way, so that a pattern will emerge from the data that has been netted. The results showed that houses that have electrical installations in accordance with the PUIL 2011 standard for each item are in the very good category with a percentage of 100% obtained on switches and MCBs, 86% on Lighting Arrangements and Lamp Fittings. In the poor category with a percentage of 50% obtained on the delivery. In the bad category with a percentage of 34% in the contact box, 44% obtained in CBF, 10% obtained in grounding installations. Keywords: Electrical Installation, PUIL 2011, Residential House.

Item Type: Thesis (Sarjana)
Additional Information: 1). Drs. Readysal Monantun, M.Pd. ; 2). Dr. Daryanto, MT.
Subjects: Teknologi dan Ilmu Terapan > Teknik Energi > Energi Listrik
Bahasa dan Kesusastraan > Bahasa Inggris
Bahasa dan Kesusastraan > Bahasa Indonesia
Teknologi dan Ilmu Terapan > Teknik Elektronika
Divisions: FT > S1 Pendidikan Teknik Elektro
Depositing User: Users 21547 not found.
Date Deposited: 02 Feb 2024 05:35
Last Modified: 02 Feb 2024 05:35
URI: http://repository.unj.ac.id/id/eprint/44026