INTENSITAS PENERANGAN PADA RUANG KERJA KANTOR KELURAHAN KEMBANGAN UTARA MENGGUNAKAN SOFTWARE DIALUX Evo 11.1

OLYVIA ANGGRAENI, . (2024) INTENSITAS PENERANGAN PADA RUANG KERJA KANTOR KELURAHAN KEMBANGAN UTARA MENGGUNAKAN SOFTWARE DIALUX Evo 11.1. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.

[img] Text
COVER.pdf

Download (914kB)
[img] Text
BAB 1.pdf

Download (142kB)
[img] Text
BAB 2.pdf
Restricted to Registered users only

Download (260kB) | Request a copy
[img] Text
BAB 3.pdf
Restricted to Registered users only

Download (360kB) | Request a copy
[img] Text
BAB 4.pdf

Download (2MB)
[img] Text
BAB 5.pdf
Restricted to Registered users only

Download (110kB) | Request a copy
[img] Text
DAFTAR PUSTAKA.pdf

Download (203kB)
[img] Text
LAMPIRAN.pdf
Restricted to Registered users only

Download (1MB) | Request a copy

Abstract

Tujuan pada penelitian ini (1) Mengetahui intensitas penerangan pada ruang kerja di Kantor Kelurahan Kembangan Utara Jakarta Barat berdasarkan standar penerangan SNI 6197 : 2020 dengan pengukuran manual dan simulasi menggunakan software Dialux evo 11.1. (2) Mengetahui perbandingan intensitas penerangan antara hasil pengukuran manual dan simulasi menggunakan software dialux evo 11.1. (3) Memberikan optimalisasi desain perbaikan terhadap ruang kerja di Kantor Kelurahan Kembangan Utara Jakarta Barat. Pada penelitian ini menggunakan jenis penelitian deskriptif kuantitatif dengan menggunakan cara pengukuran manual menggunakan luxmeter dan simulasi menggunakan perangkat lunak Dialux evo 11.1 untuk mendapatkan nilai intensitas penerangan yang sesuai SNI. Teknik pengumpulan data pada penelitian ini dilakukan dengan cara observasi dan dokumentasi. Hasil pada penelitian menunjukkan bahwa (1) Nilai rata-rata intensitas penerangan dari hasil pengukuran menggunakan lux meter dan simulasi perangkat lunak Dialux Evo 11.1 di Ruang Kerja Kantor Kelurahan Kembangan Utara Jakarta Barat, hasil yang diperoleh belum sesuai dengan standar SNI 6197:2020 seperti Ruang Pelayanan, Ruang Satpol PP, Ruang Lurah, Ruang Bendahara, dan Ruang Kasi dan Staff. Sedangkan terdapat hasil yang melampaui nilai standar yaitu Ruang PTSP, Ruang Dukcapil, Ruang Aula, dan Ruang Sekretaris. (2) Hasil pengukuran menggunakan luxmeter dan simulasi Dialux evo 11.1 pada tiga waktu yaitu pagi hari, siang hari, dan sore hari dengan kondisi asli pada ruangan menunjukkan presentase perbedaan paling kecil terdapat di Ruang Aula pada waktu siang hari sebesar 0.2%, sementara presentase paling besar terdapat di Ruang Pelayanan pada waktu sore hari sebesar 6.5%. (3) Hasil optimalisasi intensitas penerangan menggunakan simulasi Dialux Evo 11.1 merupakan desain perbaikan penerangan yang paling memenuhi standar yang diharapkan yaitu seperti optimalisasi mengubah daya watt lampu untuk ruangan yang belum memenuhi standar dan dapat menggunakan tirai untuk ruangan yang melampaui nilai standar atau silau. Setelah dilakukan optimalisasi mengalami kenaikan 27.9% sampai dengan 135.1% dan ruang kerja di Kelurahan Kembangan Utara sudah memenuhi standar minimum SNI 6197 : 2020. Kata Kunci: Intensitas Penerangan, Ruang Kerja, Dialux Evo 11.1 The objectives of this research are (1) To determine the intensity of lighting in the work space at the Kembangan Utara District Office, West Jakarta based on the SNI 6197: 2020 lighting standards by manual measurement and simulation using Dialux evo 11.1 software. (2) Knowing the comparison of lighting intensity between manual measurement results and simulations using Dialux EVO 11.1 software. (3) Providing optimization of design improvements to the work space at the Kembangan Utara District Office, West Jakarta. This research uses quantitative descriptive research using manual measurements using a luxmeter and simulation using Dialux evo 11.1 software to obtain lighting intensity values that comply with SNI. Data collection techniques in this research were carried out by means of observation and documentation. The results of the research show that (1) The average value of lighting intensity from the results of manual measurements and Dialux evo 11.1 simulations does not meet the SNI 6197: 2020 standard. The intensity standard in the Work Room is 350 lux, the lighting intensity standard in the Service Room is 300 lux, and the standard The intensity of lighting in the Hall is 300 lux. (2) The results of measurements using a luxmeter and Dialux evo 11.1 simulation at three times, namely morning, afternoon and evening with original conditions in the room, show that the smallest percentage difference is in the Hall Room during the day at 0.2%, while the highest percentage The largest number is in the Service Room in the afternoon at 6.5%. (3) The results of optimizing lighting intensity using the Dialux evo 11.1 simulation are lighting improvement designs that best meet the expected standards, such as optimizing changes in lamp wattage and being able to use curtains, which have increased by 4.7% to 135.1% and work spaces in Kembangan Utara Subdistrict meet the minimum SNI standards. 6197 : 2020. Keywords: Illumination Intensity, Workspace, Dialux Evo 11.1

Item Type: Thesis (Sarjana)
Additional Information: 1. Drs. Readysal Monantun, M.Pd. 2. Massus Subekti, S.Pd., M.T.
Subjects: Teknologi dan Ilmu Terapan > Teknik Energi > Energi Listrik
Teknologi dan Ilmu Terapan > Konstruksi Bangunan
Teknologi dan Ilmu Terapan > Teknik Elektronika
Teknologi dan Ilmu Terapan > Teknik Komputer
Divisions: FT > S1 Pendidikan Teknik Elektro
Depositing User: Users 21613 not found.
Date Deposited: 01 Feb 2024 05:08
Last Modified: 01 Feb 2024 05:08
URI: http://repository.unj.ac.id/id/eprint/44027

Actions (login required)

View Item View Item