ANALISIS KESESUAIAN INSTALASI LISTRIK DI HOTEL AYOLA LIPPO CIKARANG BERDASARKAN STUDI PUIL 2011

REZKIANA EKA HIDAYAT, . (2024) ANALISIS KESESUAIAN INSTALASI LISTRIK DI HOTEL AYOLA LIPPO CIKARANG BERDASARKAN STUDI PUIL 2011. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.

[img] Text
COVER.pdf

Download (1MB)
[img] Text
BAB 1.pdf

Download (144kB)
[img] Text
BAB 2.pdf
Restricted to Registered users only

Download (614kB) | Request a copy
[img] Text
BAB 3.pdf
Restricted to Registered users only

Download (249kB) | Request a copy
[img] Text
BAB 4.pdf
Restricted to Registered users only

Download (955kB) | Request a copy
[img] Text
BAB 5.pdf
Restricted to Registered users only

Download (80kB) | Request a copy
[img] Text
DAFTAR PUSTAKA.pdf

Download (118kB)
[img] Text
LAMPIRAN.pdf
Restricted to Registered users only

Download (3MB) | Request a copy

Abstract

Penelitian ini bertujuan untuk mengetahui kesesuaian instalasi listrik di Hotel Ayola Lippo Cikarang berdasarkan PUIL 2011. Penelitian ini menggunakan metode deskriptif kuantitatif. Pengumpulan data dilakukan dengan observasi terhadap desain instalasi listrik, penghantar instalasi listrik, pengaman beban instalasi listrik, pemasangan komponen instalasi listrik, dan instalasi listrik di dalam kamar mandi. Data yang diperoleh baik data primer maupun data sekunder akan diolah untuk mengetahui kesesuaian instalasi listrik dengan PUIL 2011. Pada pemeriksaan desain instalasi listrik seluruhnya mendapat kriteria tidak sesuai karena terdapat beberapa poin pemeriksaan yang tidak terpenuhi. Seluruh penghantar fasa yang digunakan pada instalasi listrik di Hotel Ayola Lippo Cikarang sudah sesuai hasil perhitungan arus dan KHA-nya berdasarkan PUIL 2011. Namun untuk penghantar proteksi ditemukan hanya 34 penghantar proteksi yang sesuai dengan PUIL 2011 dari 82 penghantar proteksi yang ada sehingga pada pemeriksaan ini mendapat kriteria tidak sesuai. Kemudian, belum seluruh pengaman memenuhi perbandingan IB ≤ In ≤ IZ yang berarti arus nominal pengaman (In) harus lebih besar daripada arus beban (IB) dan lebih kecil daripada KHA penghantar (IZ), dari 82 pengaman yang ada hanya 69 yang sesuai. Pada pemeriksaan pemasangan komponen instalasi listrik. Pada pemasangan komponen instalasi listrik, hanya pemasangan sakelar, konduit, dan standar perlengkapan listrik yang sudah sesuai dengan ketentuan PUIL 2011. Masih terdapat pemasangan komponen instalasi listrik yang tidak sesuai dengan PUIL 2011 sebagai contoh penandaan pada komponen instalasi listrik seperti MCB dan PHBK pasangan luar yang terdapat lubang dibagian atasnya yang dapat menyebabkan masuknya binatang kecil maupun tetesan air. Instalasi listrik di dalam kamar mandi untuk sakelar sudah sesuai standar PUIL 2011 karena tidak ditemukan sakelar yang dipasang di kamar mandi. Untuk kotak kontak tidak sesuai standar PUIL 2011 karena dipasang tanpa dilengkapi dengan transformator pemisah, atau disuplai dengan voltase ekstra rendah, atau diproteksi dengan GPAS yang memiliki arus operasi sisa tidak melebihi 30 mA, atau kotak kontak harus berjarak minimum 0,60 m dari lubang pintu pancuran air. Kemudian untuk perkawatan di atas pancuran air tentunya sangat berbahaya apabila tidak dilindungi oleh konduit dengan baik, sehingga mendapat kriteria tidak sesuai. Kata Kunci: Kesesuaian, Instalasi Listrik, Instalasi Listrik Hotel, PUIL 2011. This study aims to determine the suitability of electrical installations at Ayola Lippo Hotel Cikarang based on PUIL 2011. This study used quantitative descriptive method. Data collection was carried out by observation of the design of electrical installations, conductors of electrical installations, load safety of electrical installations, installation of electrical installation components, and electrical installations in the bathroom. The data obtained both primary and secondary data will be processed to determine the suitability of electrical installations with PUIL 2011. In the inspection of the electrical installation design, all of them received inappropriate criteria because there were several inspection points that were not met. All phase conductors used in electrical installations at Ayola Hotel Lippo Cikarang are in accordance with the results of current and KHA calculations based on PUIL 2011. However, for protection conductors, only 34 protection conductors were found to be in accordance with the 2011 PUIL out of 82 existing protection conductors so that this examination received inappropriate criteria. Then, not all safeguards meet the IB ≤ In ≤ IZ ratio which means that the nominal current of the safety (In) must be greater than the load current (I B) and smaller than the conducting KHA (IZ), of the 82 existing safeguards only 69 are suitable. On inspection of the installation of components of electrical installations. In the installation of electrical installation components, only the installation of switches, conduits, and electrical equipment standards are in accordance with the provisions of PUIL 2011. There are still installations of electrical installation components that are not in accordance with PUIL 2011 as an example of marking on electrical installation components such as MCB and PHBK outer pairs that have holes at the top that can cause the entry of small animals and water droplets. The electrical installation in the bathroom for the switch is in accordance with PUIL 2011 standards because no switch is installed in the bathroom. For contact boxes not according to PUIL 2011 standards because they are installed without being equipped with a separator transformer, or supplied with extra low voltage, or protected with GPAS that has a residual operating current not exceeding 30 mA, or the contact box must be at least 0.60 m away from the shower door hole. Then for the wiring on the shower, of course, it is very dangerous if it is not protected by conduit properly, so it gets inappropriate criteria. Keywords: suitability, electrical installation, hotel electrical installation, PUIL 2011

Item Type: Thesis (Sarjana)
Additional Information: 1). Massus Subekti, S.Pd., M.T. 2). Prof. Dr. Suyitno, M.Pd.
Subjects: Teknologi dan Ilmu Terapan > Teknologi (umum)
Teknologi dan Ilmu Terapan > Konstruksi Bangunan
Divisions: FT > S1 Pendidikan Teknik Elektro
Depositing User: Users 21562 not found.
Date Deposited: 01 Feb 2024 06:47
Last Modified: 01 Feb 2024 06:47
URI: http://repository.unj.ac.id/id/eprint/44087

Actions (login required)

View Item View Item