FERNANDO NDELAVEGA, . (2024) ANALISIS KESESUAIAN INSTALASI LISTRIK RUMAH IBADAH DENGAN KRITERIA PUIL 2020 (Studi pada Gereja Pantekosta di Indonesia Jakarta Pusat). Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.
Text
COVER.pdf Download (1MB) |
|
Text
BAB I.pdf Download (211kB) |
|
Text
BAB 2.pdf Restricted to Registered users only Download (604kB) | Request a copy |
|
Text
BAB 3.pdf Restricted to Registered users only Download (365kB) | Request a copy |
|
Text
BAB 4.pdf Restricted to Registered users only Download (700kB) | Request a copy |
|
Text
BAB 5.pdf Restricted to Registered users only Download (146kB) | Request a copy |
|
Text
DAFTAR PUSTAKA.pdf Download (202kB) |
|
Text
LAMPIRAN.pdf Restricted to Registered users only Download (1MB) | Request a copy |
Abstract
ANALISIS KESESUAIAN INSTALASI LISTRIK RUMAH IBADAH DENGAN KRITERIA PUIL 2020 (Studi pada Gereja Pantekosta di Indonesia Jakarta Pusat) Fernando Ndelavega Dosen Pembimbing: Drs. Readysal Monantun, M.Pd. dan Prof. Dr. Suyitno M., M.Pd. ABSTRAK Tujuan dari penelitian ini adalah untuk menentukan kesesuaian perlengkapan listrik dan instalasi listrik di Gereja Pantekosta di Indonesia di Jakarta Pusat berdasarkan PUIL 2020. Semakin bertambahnya umur suatu bangunan dan menurunnya kualitas instalasi listriknya. Dan akan berpengaruh terhadap keamanan instalasi listrik serta keselamatan pemakainya. Penelitian ini menggunakan metode survei dengan pendekatan deskriptif kuantitatif. Pengumpulan data menggunakan teknik observasi dan dokumentasi serta wawancara. Sample penelitian ini terdapat 11 ruangan yang berada di Gereja Pantekosta di Indonesia di Jl. Kramat Raya No.65, RT.1/RW.8, Kramat, Kec. Senen, Kota Jakarta Pusat, Daerah Khusus Ibukota Jakarta 10450, Indonesia. Pemeriksaan dan pengukuran instalasi dilakukan pada aspek item uji penghantar, PSDK, sakelar, stopkontak dan pembumian serta tahanan isolasi. Dalam menentukan tingkat kesesuaian instalasi listrik jika dilihat dari aspek item uji, penilaian instalasi listrik tergantung pada hasil pengamatan dan pengukuran, dimana hasilnya tersebut disesuaikan dengan PUIL 2020. Berdasarkan data peneliti yang tersaring dapat disimpulkan bahwa tingkat kesesuaian Instalasi listrik di Gereja Pantekosta di Indonesia di Jakarta Pusat rata-rata kurang sesuai PUIL 2020 dengan rincian kategori sebagai berikut : kategori sesuai sebanyak 27,28%, kategori cukup sesuai sebanyak 72,72% dan kategori kurang sesuai sebanyak 0% serta kategori tidak sesuai sebanyak 0%. Kata kunci : PUIL 2020, Kesesuaian, Instalasi listrik, Gereja. ANALYSIS OF THE COMPATIBILITY OF ELECTRIACAL INSTALLATIONS IN HOUSE OF PRAYERS WITH THE CRITERIA OF PUIL 2020 (Case Study on Pantecostal Church in Central Jakarta, Indonesia) Fernando Ndelavega Advisor: Drs. Readysal Monantun, M.Pd. and Prof. Dr. Suyitno M., M.Pd. ABSTRACT The purpose of this study is to determine the feasibility of electrical equipment and electrical installations in Pentecostal Church in Indonesia in Central Jakarta based on PUIL 2020. As the age of a building increases, the quality of its electrical installation decreases. And it will affect the security of electrical installations and the safety of users. This research uses a survey method with a quantitative descriptive approach. Data collection uses observation and documentation techniques as well as interviews. The sample for this research consisted of 11 rooms in the Pentecostal Church in Indonesia on Jl. Kramat Raya No.65, RT.1/RW.8, Kramat, Kec. Senen, Central Jakarta City, Special Capital Region of Jakarta 10450, Indonesia. Inspection and measurement of installations are carried out on aspects of conducting test items, PSDK, switches, electric socket and earthing boxes and insulation resistance. In determining the level of suitability of electrical installations when viewed from the test item aspect, the assessment of electrical installations depends on the results of observations and measurements, where the results are adjusted to PUIL 2020. Based on filtered research data, it can be concluded that the level of suitability of electrical installations in Pentecostal Churches in Indonesia in Jakarta The average center does not comply with PUIL 2020 with the following category details: the appropriate category is 27.28%, the quite appropriate category is 72.72% and the less suitable category is 0% and the inappropriate category is 0%. Keywords: PUIL 2020, Airworthiness, Electrical installation, Church
Item Type: | Thesis (Sarjana) |
---|---|
Additional Information: | 1). Drs. Readysal Monantun, M.Pd. 2). Prof. Dr. Suyitno M., M.Pd. |
Subjects: | Teknologi dan Ilmu Terapan > Teknik Energi > Energi Listrik |
Divisions: | FT > S1 Pendidikan Teknik Elektro |
Depositing User: | Users 21144 not found. |
Date Deposited: | 02 Feb 2024 04:43 |
Last Modified: | 02 Feb 2024 04:43 |
URI: | http://repository.unj.ac.id/id/eprint/44190 |
Actions (login required)
View Item |