ANALISIS KELAIKAN INSTALASI LISTRIK PADA BANGUNAN BERTINGKAT BERDASARKAN PUIL 2011 (STUDI KASUS PADA SMKN 55 JAKARTA)

AFIFA FITRIYANI, . (2024) ANALISIS KELAIKAN INSTALASI LISTRIK PADA BANGUNAN BERTINGKAT BERDASARKAN PUIL 2011 (STUDI KASUS PADA SMKN 55 JAKARTA). Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.

[img] Text
COVER.pdf

Download (5MB)
[img] Text
BAB I.pdf

Download (123kB)
[img] Text
BAB II.pdf
Restricted to Registered users only

Download (883kB) | Request a copy
[img] Text
BAB III.pdf
Restricted to Registered users only

Download (291kB) | Request a copy
[img] Text
BAB IV.pdf
Restricted to Registered users only

Download (571kB) | Request a copy
[img] Text
BAB V.pdf
Restricted to Registered users only

Download (52kB) | Request a copy
[img] Text
DAFTAR PUSTAKA.pdf

Download (112kB)
[img] Text
LAMPIRAN.pdf
Restricted to Registered users only

Download (1MB) | Request a copy

Abstract

Penelitian ini bertujuan untuk mengetahui kelaikan instalasi listrik di SMKN 55 Jakarta dengan standar Persyaratan Umum Instalasi Listrik (PUIL) 2011. Mengingat dampak membahayakan yang dapat terjadi apabila salah dalam penggunaan listrik yaitu dapat terjadi kebakaran, untuk menghindari resiko bahaya listrik perlu diketahui kelaikan instalasi listrik yang terpasang, guna memastikan keamanan terhadap instalasi tersebut dengan melakukan pemeriksaan secara berkala. Penelitian ini menggunakan metode deskriptif kuantitatif. Pengumpulan data menggunakan teknik observasi dan dokumentasi. Pemeriksaan dan pengukuran instalasi dilakukan pada aspek yang akan diteliti, yaitu gambar instalasi listrik dan diagram garis tunggal, penghantar, pemasangan dan polaritas komponen instalasi listrik serta instalasi kamar mandi dan PHBK. Hasil penelitian menunjukkan bahwa tingkat kelaikan gambar instalasi listrik dengan yang tepasang adalah 0% sangat laik, 75% cukup laik, 0% kurang laik dan 0% tidak laik. Tingkat kelaikan diagram garis tunggal dengan yang terpasang adalah 0% sangat laik, 75% cukup laik, 0% kurang laik dan 0% tidak laik. Tingkat kelaikan penghantar instalasi listrik adalah 10% sangat laik, 60% cukup laik, 0% kurang laik dan 30% tidak laik. Tingkat kelaikan pemasangan instalasi listrik yang terpasang adalah 33,33% sangat laik, 56,67% cukup laik, 10% kurang laik dan 0% tidak laik. Tingkat kelaikan polaritas komponen instalasi listrik adalah 73,33% sangat laik, 26,67% cukup laik, 0% kurang laik dan 0% tidak laik. Tingkat kelaikan instalasi kamar mandi adalah 66,67% sangat laik, 33,33% cukup laik, 0% kurang laik dan 0% tidak laik. Tingkat kelaikan perlengkapan instalasi listrik yang terpasang berstandar SNI adalah 90% sangat laik, 6,67% cukup laik, 3,33% kurang laik dan 0% tidak laik. Tingkat kelaikan PHBK yang terpasang adalah 80% sangat laik, 20% cukup laik, 0% kurang laik dan 0% tidak laik. Dari hasil penelitian dapat disimpulkan bahwa pemasangan instalasi Listrik pada SMKN 55 Jakarta cukup laik dan cukup sesuai dengan standar PUIL 2011, mengingat masih terdapat beberapa kriteria instalasi listrik yang tidak memenuhi standar. Kata kunci: PUIL 2011, Kelaikan, Instalasi Listrik, Sekolah ***** This study aims to determine the feasibility of electrical installations at SMKN 55 Jakarta with the 2011 General Requirements for Electrical Installations (PUIL) standards. Given the harmful impact that can occur if the wrong use of electricity is that a fire can occur, to avoid the risk of electrical hazards, it is necessary to know the feasibility of the installed electrical installation, to ensure the safety of the installation by conducting periodic checks. This study used quantitative descriptive method. Data collection using observation and documentation techniques. Inspection and measurement of installations are carried out on the aspects to be studied, namely electrical installation drawings and single line diagrams, conductors, installation and polarity of electrical installation components as well as bathroom installations and PHBK. The results showed that the level of feasibility of the electrical installation drawings with those installed was 0% very feasible, 75% quite feasible, 0% less feasible and 0% not feasible. The feasibility level of a single line chart with installed is 0% very feasible, 75% quite feasible, 0% less feasible and 0% not feasible. The level of airworthiness of electrical installation conductors is 10% very feasible, 60% quite feasible, 0% less feasible and 30% not feasible. The feasibility rate of installing installed electrical installations is 33.33% very feasible, 56.67% quite feasible, 10% less feasible and 0% not feasible. The level of feasibility of the polarity of electrical installation components is 73.33% very feasible, 26.67% quite feasible, 0% less feasible and 0% not feasible. The feasibility rate of bathroom installation is 66.67% very feasible, 33.33% quite feasible, 0% less feasible and 0% not feasible. The feasibility level of electrical installation equipment installed with SNI standards is 90% very feasible, 6.67% quite feasible, 3.33% less feasible and 0% not feasible. The installed PHBK feasibility level is 80% very feasible, 20% quite feasible, 0% less feasible and 0% not feasible. From the results of the study, it can be concluded that the installation of electrical installations at SMKN 55 Jakarta is not feasible and not in accordance with the 2011 PUIL standards, considering that there are still several electrical installation criteria that do not meet the standards. Keywords: PUIL 2011, Airworthiness, Electrical Installation, School

Item Type: Thesis (Sarjana)
Additional Information: 1). Drs. Readysalh Monantun, M.Pd. ; 2). Massus Subekti, S.Pd., M.T.
Subjects: Teknologi dan Ilmu Terapan > Teknik Energi > Energi Listrik
Bahasa dan Kesusastraan > Bahasa Inggris
Bahasa dan Kesusastraan > Bahasa Indonesia
Teknologi dan Ilmu Terapan > Konstruksi Bangunan
Teknologi dan Ilmu Terapan > Teknik Elektronika
Divisions: FT > S1 Pendidikan Teknik Elektro
Depositing User: Users 21570 not found.
Date Deposited: 05 Feb 2024 01:37
Last Modified: 05 Feb 2024 01:37
URI: http://repository.unj.ac.id/id/eprint/44301

Actions (login required)

View Item View Item