FARHAN MUHAMMAD RIZKY, . (2024) SPEKTROMETER CAHAYA TAMPAK UNTUK ANALISIS ABSORBANSI METHYLENE BLUE (MB). Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.
Text
COVER.pdf Download (1MB) |
|
Text
BAB I.pdf Download (248kB) |
|
Text
BAB II.pdf Restricted to Repository staff only Download (820kB) | Request a copy |
|
Text
BAB III.pdf Restricted to Repository staff only Download (582kB) | Request a copy |
|
Text
BAB IV.pdf Restricted to Repository staff only Download (1MB) | Request a copy |
|
Text
BAB V.pdf Restricted to Repository staff only Download (173kB) | Request a copy |
|
Text
DAFTAR PUSTAKA.pdf Download (254kB) |
|
Text
LAMPIRAN.pdf Restricted to Repository staff only Download (485kB) | Request a copy |
Abstract
Pencemaran kualitas air yang berasal dari air limbah pewarna menjadi salah satu tantangan dalam bidang industri tekstil. Salah satu pewarna yang sering digunakan yaitu Methylene Blue (MB). Salah satu solusi yang dapat dilakukan yaitu dengan membuat sistem pemantauan dengan alat laboratorium spektrometer. Spektrometer mampu mengukur absorbansi cahaya pada suatu larutan. Penelitian ini dilakukan untuk mengembangkan perangkat spektrometer cahaya tampak untuk menentukan nilai absorbansi methylene blue dan mengaplikasikan dalam pengukuran konsentrasi sample larutan methylene blue. Metode yang digunakan dalam penelitian ini adalah pengembangan alat dan eksperimen dengan berbagai variasi nilai konsentrasi. Kemudian hasil intensitas cahaya yang didapat diolah menjadi absorbansi lalu dibuat plot spektrum absorbansi pada rentang panjang gelombang 400 – 700 nm. Hasil puncak tertinggi didapat pada panjang gelombang 652 nm. Lalu peneliti menganalisis dua panjang gelombang yaitu 489.8 nm dan 538.0 nm untuk mendapatkan koefisien ekstringsi spesifik yang bernilai sebesar 98.34767 98.34767 ml/g∙cm dan 91.41522 ml/g∙cm. Dengan menggunakan sample tambahan, peneliti mendapatkan nilai konsentrasi dengan nilai error pada panjang gelombang 489.8 nm dan 538.0 nm sebesai 3.363182% dan 4.578155%. ************************************************************ Water pollution originating from dye wastewater is a significant challenge in the textile industry. One of the commonly used dyes is Methylene Blue (MB). One solution to this problem is developing a monitoring system using a laboratory spectrometer. A spectrometer can measure the light absorbance of a solution. This study aims to develop a visible light spectrometer device to determine the absorbance value of methylene blue and apply it to measure the concentration of methylene blue solution samples. The method used in this research involves developing the instrument and conducting experiments with various concentration values. The light intensity results obtained were processed into absorbance and then plotted into an absorbance spectrum within the wavelength range of 400 – 700 nm. The highest peak was observed at a wavelength of 652 nm. Additionally, the researchers analyzed two wavelengths, 489.8 nm and 538.0 nm, to obtain specific extinction coefficients of 98.34767 ml/g∙cm and 91.41522 ml/g∙cm, respectively. Using additional samples, the researchers found concentration values with errors of 3.363182% and 4.578155% at wavelengths of 489.8 nm and 538.0 nm, respectively.
Item Type: | Thesis (Sarjana) |
---|---|
Additional Information: | 1). Dr. Hadi Nasbey, S.Pd., M.Si. ; 2). Haris Suhendar, S.Si., M.Sc. |
Subjects: | Sains > Fisika |
Divisions: | FMIPA > S1 Fisika |
Depositing User: | Users 24501 not found. |
Date Deposited: | 13 Aug 2024 00:36 |
Last Modified: | 13 Aug 2024 00:36 |
URI: | http://repository.unj.ac.id/id/eprint/49166 |
Actions (login required)
View Item |