SULTHAN YASYKUR KHAIRULLAH SUN, . (2026) EVALUASI KEANDALAN SISTEM KESELAMATAN KEBAKARAN PADA BANGUNAN CAGAR BUDAYA BERDASARKAN PD - T – 11 - 2005 - C DENGAN PENDEKATAN ANALISIS KESENJANGAN : STUDI KASUS SDN 07 PALMERAH, JAKARTA. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.
|
Text
Cover.pdf Download (1MB) |
|
|
Text
BAB I.pdf Download (308kB) |
|
|
Text
BAB II.pdf Restricted to Registered users only Download (396kB) | Request a copy |
|
|
Text
BAB III.pdf Restricted to Registered users only Download (538kB) | Request a copy |
|
|
Text
BAB IV.pdf Restricted to Registered users only Download (1MB) | Request a copy |
|
|
Text
BAB V.pdf Restricted to Registered users only Download (301kB) | Request a copy |
|
|
Text
Daftar Pustaka.pdf Download (263kB) |
|
|
Text
Lampiran.pdf Restricted to Registered users only Download (1MB) | Request a copy |
Abstract
Bangunan cagar budaya memiliki nilai sejarah dan arsitektural yang perlu dilestarikan, namun tetap harus memenuhi aspek keselamatan kebakaran. Penerapannya menjadi tantangan karena keterbatasan intervensi terhadap elemen bangunan yang dilestarikan. Penelitian ini mengevaluasi keandalan sistem keselamatan kebakaran SDN 07 Palmerah, Jakarta, berdasarkan Pd-T-11-2005-C menggunakan pendekatan analisis kesenjangan. Data dikumpulkan melalui observasi, dokumentasi, dan pengukuran pada empat komponen: kelengkapan tapak, sarana penyelamatan, proteksi aktif, dan proteksi pasif. Hasil evaluasi menunjukkan ketidaksesuaian terhadap kriteria Pd-T-11-2005-C dengan nilai Keandalan Sistem Keselamatan Bangunan (NKSKB) eksisting sebesar 64,082% (kategori Cukup). Penerapan rekomendasi adaptif melalui intervensi langsung dan compensatory features (NFPA 914, Pasal 8.2) diproyeksikan meningkatkan NKSKB menjadi 81,68% (kategori Baik). Rekomendasi diarahkan pada strategi minimal intervensi yang mempertimbangkan keterbatasan perubahan terhadap elemen bangunan yang dilestarikan. ***** Heritage buildings possess historical and architectural values that need to be preserved while maintaining adequate fire safety. Their implementation becomes challenging due to intervention limitations on preserved building elements. This study evaluates the fire safety reliability of SDN 07 Palmerah, Jakarta, based on Pd-T-11-2005-C using a gap analysis approach. Data were collected through observation, documentation, and measurement across four components: site facilities, means of egress, active protection, and passive protection. The results indicate discrepancies with Pd-T-11-2005-C criteria, with an existing Building Fire Safety System Reliability Value (NKSKB) of 64.082% (Fair category). The implementation of adaptive recommendations through direct interventions and compensatory features (NFPA 914, Section 8.2) is projected to increase the NKSKB to 81.68% (Good category). The recommendations are directed toward minimally invasive strategies that consider limitations on modifications to preserved building elements.
| Item Type: | Thesis (Sarjana) |
|---|---|
| Additional Information: | 1). Pratomo Setyadi, S.T.,M.T; 2). Ir. Waradzi Mustakim, S.T.,M.Pd.T. |
| Subjects: | Teknologi dan Ilmu Terapan > Konstruksi Bangunan |
| Divisions: | FT > S1 Rekayasa Keselamatan Kebakaran |
| Depositing User: | Sulthan Yasykur Khairullah Sun . |
| Date Deposited: | 05 Oct 2026 07:02 |
| Last Modified: | 05 Oct 2026 07:02 |
| URI: | http://repository.unj.ac.id/id/eprint/74030 |