APLIKASI ANDROID UNTUK RANCANG BANGUN SISTEM PENGUKURAN KEKERUHAN DAN JUMLAH ZAT PADAT TERLARUT DALAM AIR BERBASIS ARDUINO

ZULFIAH AYU KURNIA SARI, . (2017) APLIKASI ANDROID UNTUK RANCANG BANGUN SISTEM PENGUKURAN KEKERUHAN DAN JUMLAH ZAT PADAT TERLARUT DALAM AIR BERBASIS ARDUINO. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.

[img] Text
SKRIPSI_Zulfiah Ayu Kurnia Sari_3225136375.pdf

Download (3MB)

Abstract

Telah dibuat sistem pengukuran kekeruhan dan jumlah zat padat terlarut dalam air guna membantu masyarakat dalam mengetahui kualitas air dalam parameter tersebut. Rancang bangun ini dilengkapi dengan sensor suhu ds18b20 sebagai pengukur suhu, sensor photodioda sebagai pengukur kekeruhan, dan sensor konduktivitas sebagai pengukur jumlah zat padat terlarut (TDS) dalam air, serta menggunakan arduino sebagai mikrokontrolernya. Pengujian kekeruhan dan jumlah zat padat terlarut dilakukan di Laboratorium Kesehatan sebagai data pembanding dalam proses kalibrasi sensor photodioda dan sensor konduktivitas. Hasil pengujian keseluruhan sistem ditampilkan pada aplikasi android. Rancang bangun ini dapat bekerja baik dalam mendeteksi kekeruhan pada rentang 3-77 NTU dengan kesalahan relatif pengukuran sebesar 3.13%, dan dapat mendeteksi jumlah zat padat terlarut pada rentang 24-1300 ppm dengan kesalahan relatif pengukuran sebesar 2.42%, serta mendeteksi suhu dengan kesalahan relatif pengukuran sebesar 0.54%. A turbidity measurement system and total dissolved solid in water has been developed to assist people in knowing the water quality in these parameters. The design is equipped with a temperature sensor ds18b20 as a temperature measurement, a photodioda sensor as turbidity measurement, and conductivity sensor as a measure of total dissolved solid (TDS) in water, and using arduino as its microcontroller. The turbidity and total dissolved solid tested at the Health Laboratory as comparative data in calibration process of photodiode and conductivity sensor. The results of the entire system test are displayed on android application. This design works well in detecting turbidity in range 3-77 NTU with the relative error measurement 3.13%, and can detect total dissolved solid in range 24-1300 ppm with the relative error measurement 2.42%, also can detect temperature with relative error measurement 0.54%.

Item Type: Thesis (Sarjana)
Additional Information: 1) Dr. Widyaningrum Indrasari, M.Si 2) Drs. Handjoko Permana, M.Si
Subjects: Sains > Fisika
Divisions: FMIPA > S1 Fisika
Depositing User: sawung yudo
Date Deposited: 20 Apr 2022 06:14
Last Modified: 20 Apr 2022 06:14
URI: http://repository.unj.ac.id/id/eprint/27252

Actions (login required)

View Item View Item