RIA SEPTIYANTHY, . (2015) ANALISIS PENERAPAN SISTEM PENANGKAL PETIR YANG DIGUNAKAN PADA GEDUNG PUSAT PERBELANJAAN (Studi Kasus di Mall Kota Kasablanka). Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.
Text
3. HALAMAN PERNYATAAN.pdf Download (9MB) |
|
Text
5._ABSTRAK_(INDONESIA).pdf Download (86kB) |
|
Text
4._KATA_PENGANTAR.pdf Download (166kB) |
|
Text
2. HALAMAN PENGESAHAN.pdf Download (3MB) |
|
Text
1._COVER.pdf Download (14kB) |
|
Text
7._DAFTAR_ISI.pdf Download (223kB) |
|
Text
8._BAB_I.pdf Download (182kB) |
|
Text
9._BAB_II.pdf Download (1MB) |
|
Text
6._ABSTRAK_(ENGLISH).pdf Download (85kB) |
|
Text
10._BAB_III.pdf Download (409kB) |
|
Text
13._DAFTAR_PUSTAKA.pdf Download (91kB) |
|
Text
14._BIODATA_PENULIS.pdf Restricted to Registered users only Download (173kB) |
|
Text
11._BAB_IV.pdf Download (1MB) |
|
Text
12._BAB_V.pdf Download (168kB) |
Abstract
Penelitian ini bertujuan untuk menganalisis efisiensi sistem proteksi (level proteksi) dan radius perlindungan sistem penangkal petir eksternal terhadap bangunan bertingkat seperti gedung pusat perbelanjaan Mall Kota Kasablanka. Metode yang digunakan dalam penelitian ini adalah metode penelitian deskriptif atau survey dan memperoleh data dengan fakta yang akurat berdasarkan obeservasi yang dilakukan. Dimana peneliti mengobservasi sistem penangkal petir eksternal yang digunakan serta mengevaluasi bagaimana efisiensi sistem proteksi (level proteksi) dan radius perlindungan sistem penangkal petir eksternal tersebut serta bagaimana area proteksi mall terhadap sambaran petir. Hasil penelitian Gedung Mall Kota Kasablanka menggunakan penagkal petir jenis ESE (Early Streamer Emission) yaitu Prevectron 2 Millenium tipe S 6.60 dikarenakan radius proteksi 79 meter, luas area proteksi 39.193,48 m2 , dan sudut perlindungan sebesar 19,94°. Penentuan kebutuhan gedung terhadap proteksi petir berdasarkan PUIPP dan NFPA Mall Kota Kasablanka memiliki nilai yang besar yaitu 18 dan 4 sehingga dalam hal ini mall tergolong bangunan yang sangat memerlukan sistem proteksi terhadap sambaran petir. Diperoleh efisiensi proteksi petir sebesar 0,97 sehingga Mall Kota Kasablanka termasuk dalam tingkat Level Proteksi I. Kesimpulan dalam penelitian ini yaitu penggunaan jenis penangkal petir yang diterapkan pada Mall Kota Kasablanka sesuai dengan kebutuhan situasi dan kondisi bangunan sehingga luas area proteksi efektif memberikan perlindungan baik terhadap gedung maupun penghuni di dalamnya karena sejak gedung beroperasi belum pernah terjadi berbagai macam gangguan akibat adanya sambaran petir. *This research aims to analyze the efficiency of protection system (the level of protection) and the radius protection external lightning rod system such as shopping center building, Kota Kasablanka Mall . The methods that used in this research is descriptive research methodology or survey and obtain data with the facts based on accurate obeservasi conducted .Where researchers obseved a system of external lightning rod used as well as evaluate where efficiency protection system (the level of protection) and radius protection system lightning rod external the location and how mall area protection against of a bolt of lightning. The results of research Kota Kasablanka Mall use lightning ESE Rod (Early Streamer Emission) is prevectron 2 of the millennium type S 6.60 radius protection because 79 meters , broad protection area 39.193,48 m2 , and angles protection of 19,94°.The determination of the needs of the building against lightning protection based on puipp and nfpa mall city kasablanka having great value that is 18 and 4 so that in this mall is considered to be building that really need protection system against of a bolt of lightning .Obtained efficiency lightning protection of 0,97 so that mall city kasablanka included in the level of the level of protection 1. The usage of a lightning rod applied to the Kota Kasablanka Mall based on the situation and the condition of buildings and widespread the effective protection provided protection for the good and the dwellers in those buildings so since operated yet there are various kinds of disorder due to the presence of a bolt of lightning
Item Type: | Thesis (Sarjana) |
---|---|
Additional Information: | 1). Drs.Readysal Monantun ; 2). Drs. Irzan Zakir, M.P |
Subjects: | Teknologi dan Ilmu Terapan > Konstruksi Bangunan |
Divisions: | FT > S1 Pendidikan Teknik Elektro |
Depositing User: | Users 8922 not found. |
Date Deposited: | 17 May 2022 03:19 |
Last Modified: | 17 May 2022 03:19 |
URI: | http://repository.unj.ac.id/id/eprint/28372 |