VIOLA MOENIEKA RAZZAQ, . (2023) ANALISA PEMBAGIAN BEBAN INSTALASI LISTRIK TIGA FASA (STUDI PADA GEDUNG WORKSHOP REFRIGERATOR BBPVP CEVEST BEKASI). Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.
Text
COVER.pdf Download (679kB) |
|
Text
BAB 1.pdf Download (167kB) |
|
Text
BAB 2.pdf Restricted to Registered users only Download (408kB) | Request a copy |
|
Text
BAB 3.pdf Restricted to Registered users only Download (264kB) | Request a copy |
|
Text
BAB 4.pdf Restricted to Registered users only Download (408kB) | Request a copy |
|
Text
BAB 5.pdf Restricted to Registered users only Download (155kB) | Request a copy |
|
Text
DAFTAR PUSTAKA.pdf Download (224kB) |
|
Text
LAMPIRAN.pdf Restricted to Registered users only Download (1MB) | Request a copy |
Abstract
Penelitian ini bertujuan untuk menganalisa pembagian beban pada instalasi listrik Gedung Workshop Refrigerator pada BBPVP Bekasi. Dengan menggunakan metode deskriptif kuantitatif, Penelitian yang dilakukan ialah (1) membuat diagram satu garis gedung, (2) menelusuri beban dan mengelompokkan untuk pembuatan rekapitulasi daya, (3) melakukan pengukuran daya sebagai validasi dari rekapitulasi daya dan (4) analisa pembagian beban instalasi tiga fasa dari rekapitulasi daya. Hasil penelitian yang didapat, yaitu: (1) Pada rekapitulasi daya SDP Refrigerator Lt. 1. tidak seimbang dapat diperhatikan bahwa total daya pada fasa R jauh lebih besar daripada kedua fasa lainnya disebabkan oleh beban yang mendominasi yaitu 8 unit AC Split ½ PK dengan daya 1524 Watt per unitnya. Selain menjadi daya terbesar, AC juga merupakan beban induktor sehingga mempengaruhi nilai Faktor daya yaitu 0.719. (2) Pada rekapitulasi daya SDP Trainer Area Lt. 2. dapat diperhatikan bahwa total daya pada fasa R jauh lebih besar daripada kedua fasa lainnya disebabkan oleh beban yang mendominasi yaitu 6 unit AC Split ½ PK dengan daya 1524 Watt per unitnya. Selain menjadi daya terbesar, AC juga merupakan beban induktor sehingga mempengaruhi nilai Faktor daya yaitu 0.779. (3) Pada rekapitulasi daya SDP Training Center ASC Lt. 2. dapat diperhatikan bahwa total daya pada fasa T jauh lebih besar daripada kedua fasa lainnya disebabkan oleh beban yang mendominasi yaitu 4 unit AC Split ½ PK dengan daya 1524 Watt per unitnya. Selain menjadi daya terbesar, AC juga merupakan beban induktor sehingga mempengaruhi nilai Faktor daya yaitu 0.786. (4) Pada rekapitulasi daya SDP Lab. Commercial AC/VRV dapat diperhatikan bahwa total daya pada fasa R, S, dan T cenderung seimbang karna pembagian beban yang mendominasi yaitu AC Split ½ PK dengan daya 1524 Watt per unitnya dibagikan hamper merata, sehingga faktor daya yang dihasilkan hampir sama besar Fasa R sebesar 0,789, Fasa S sebesar 0,755, dan Fasa T sebesar 0,799. (5) Keempat beban panel SDP di atas dialirkan ke panel utama atau MDP. Sehingga Faktor daya yang didapat yaitu Fasa R sebesar 0.787, Fasa S sebesar 0.851, dan Fasa T sebesar 0.811. ***** This study aims to analyze the load distribution on the electrical installation of the Refrigerator Workshop Building at BBPVP Bekasi. By using a quantitative descriptive method, the research carried out was (1) making a one-line diagram of the building, (2) tracing loads and grouping them for making power recapitulations, (3) measuring power as a validation of power recapitulation and (4) analyzing installation load sharing three phases of power recapitulation. The research results obtained are: (1) In the power recapitulation of SDP Refrigerator Lt. 1. unbalanced, it can be noted that the total power in phase R is much greater than the other two phases due to the dominating load, which is 8 AC Split ½ PK units with a power of 1524 Watt per unit. In addition to being the largest power, AC is also an inductor load so that it affects the value of the power factor, which is 0.719. (2) In the power recapitulation of the SDP Trainer Area Lt. 2. It can be noted that the total power in phase R is much greater than the other two phases due to the dominating load, namely 6 AC Split ½ PK units with a power of 1524 Watt per unit. In addition to being the biggest power, AC is also an inductor load so that it affects the value of the power factor, which is 0.779. (3) In the recapitulation of the power of the SDP Training Center ASC Lt. 2. It can be noted that the total power in phase T is much greater than the other two phases due to the dominating load, namely 4 AC Split ½ PK units with a power of 1524 Watt per unit. In addition to being the biggest power, AC is also an inductor load so that it affects the value of the power factor which is 0.786. (4) In the SDP Lab power recapitulation. In Commercial AC/VRV, it can be noted that the total power in the R, S, and T phases tends to be balanced because the distribution of the load that dominates, namely AC Split ½ PK with a power of 1524 Watt per unit is distributed almost evenly, so that the resulting power factor is almost as large as Phase R of 0.789, S phase of 0.755, and T phase of 0.799. (5) The four SDP panel loads above are streamed to the main panel or MDP. So that the power factor obtained is Phase R of 0.787, Phase S of 0.851, and Phase T of 0.811.
Item Type: | Thesis (Sarjana) |
---|---|
Additional Information: | 1). Massus Subekti, M.T. ; 2). Drs. Readysal Monantun, M.Pd. |
Subjects: | Teknologi dan Ilmu Terapan > Teknik Energi > Energi Listrik Teknologi dan Ilmu Terapan > Teknik Energi |
Divisions: | FT > S1 Pendidikan Teknik Elektro |
Depositing User: | Users 19197 not found. |
Date Deposited: | 31 Aug 2023 06:19 |
Last Modified: | 31 Aug 2023 06:19 |
URI: | http://repository.unj.ac.id/id/eprint/40299 |