PERANCANGAN FIRE GROUND DI LABORATORIUM PENDIDIKAN DAN PELATIHAN HSE & FIRE SAFETY UNIVERSITAS NEGERI JAKARTA

DAFFATHUR RACHMAN SATRIYAJI, . (2024) PERANCANGAN FIRE GROUND DI LABORATORIUM PENDIDIKAN DAN PELATIHAN HSE & FIRE SAFETY UNIVERSITAS NEGERI JAKARTA. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.

[img] Text
COVER.pdf

Download (1MB)
[img] Text
BAB 1.pdf

Download (1MB)
[img] Text
BAB 2.pdf
Restricted to Registered users only

Download (3MB) | Request a copy
[img] Text
BAB 3.pdf
Restricted to Registered users only

Download (1MB) | Request a copy
[img] Text
BAB 4.pdf
Restricted to Registered users only

Download (1MB) | Request a copy
[img] Text
BAB 5.pdf
Restricted to Registered users only

Download (926kB) | Request a copy
[img] Text
DAFTAR PUSTAKA.pdf

Download (989kB)
[img] Text
LAMPIRAN.pdf
Restricted to Registered users only

Download (1MB) | Request a copy

Abstract

Laboratorium merupakan sarana penunjang akademik, digunakan untuk melakukan aktivitas pendidikan, penetlitian, dan pengabdian masyarakan dengan menggunakan alat dan bahan berdasarkan metode keilmuan khusus. Laboratorium menjadi salah satu sarana penunjang penting yang bersifat strategis dalam aktivitas akademik. Program Studi Rekayasa Keselamatan Kebakaran Universitas Negeri Jakarta memilikki beberapa laboratorium, satu diantaranya adalah Laboratorium Pendidikan dan Pelatihan HSE & Fire Safety yang berlokasi di Kecamatan Duren Sawit, Jakarta Timur. Pada laboratorium tersebut tersedia beberapa fasilitas diantaranya ruang kelas, kamar mandi, mushola, dan aula. Fasilitas tersebut masih perlu dikembangan unuk dapat meningkatkan keterampilan mahasiswa dalam menghadapi dunia pekerjaan. Fasilitas yang dapat dikembangkan salah satunya berupa fire pool dan instalasi pipa gas untuk meningkatkan keterampilan mahasiswa dalam memadamkan api. Perancangan fire pool dan instalasi pipa gas dilakukan dengan melakukan perhitungan HRR, tinggi api, dan durasi nyala api. Diameter fire pool yang dirancang berukuran 1170mm dan kedalaman 150mm. diletakan dengan jarak radius 8 kali diameter fire pool. Hasil perhitungan dengan menggunakan bahan bakar fire pool berupa solar 13,56liter dan bensin 9,04liter. Hasil perhitungan HRR 2112kW, tinggi api 3.83m, dan durasi nyala api 371 detik. Kemudian dilakukan pembangunan serta pengujian fire pool dan instalasi pipa gas. Pengujian yang dilakukan adalah pengujian kebocoran dan uji operasional. Hasil uji kebocoran fire pool dan instalasi pipa gas memberi hasil kedua alat tidak ada kebocoran. Uji operasional menunjukkan fire pool dan instalasi aman untuk dioperasionalkan di Laboratorium Pendidikan dan Pelatihan HSE & Fire Safety Universitas Negeri Jakarta. The laboratory is a means of academic support, used to carry out educational activities, training, and teaching dedication using tools and materials based on special scientific methods. The Fire Safety Engineering Studies Program of the State University of Jakarta has several laboratories, one of which is the Education and Training Laboratory of HSE & Fire Security located in Duren Sawit district, East Jakarta. The lab has several facilities, including classrooms, bathrooms, tubs, and halls. The facility still needs to be developed in order to improve students' skills in the face of the world of work. Facilities that could be developed include fire pools and gas pipes to improve students' skills in extinguishing fires. The design of the fire pool and the installation of the gas pipes was carried out by calculating the HRR, the height of fire, and the duration of the flame. The designed fire pool diameter was 1170mm and depth 150mm. placed with a radius of 8 times the diameter of fire pool. The calculations were made using a 13.56 litre solar fire pool and 9.04 litre gasoline. HRR 2112kW, a fire height of 3.83m, and a fire length of 371 seconds. After the construction and testing of the fire pool and the installation of the gas pipes, the test is a leakage test and an operational test. The results of the test of leaks and the gas pipe installation give the results of both devices no leaks. The operational tests show fire pools and installations are safe to be operated in the Education and Training Laboratory of HSE & Fire Safety of the State University of Jakarta.

Item Type: Thesis (Sarjana)
Additional Information: 1). Dr.Ir. Triyono, S.T., M.Eng 2). Dr. Ir. Jafar Amiruddin, M.T
Subjects: Teknologi dan Ilmu Terapan > Teknik Mesin, Mekanika Teknik
Divisions: FT > S1 Rekayasa Keselamatan Kebakaran
Depositing User: Users 22906 not found.
Date Deposited: 22 Jul 2024 07:06
Last Modified: 22 Jul 2024 07:06
URI: http://repository.unj.ac.id/id/eprint/45906

Actions (login required)

View Item View Item