ATIKA MARISA DINIYAH, . (2024) PENGEMBANGAN TENSIMETER DIGITAL UNTUK PROTOTIPE ANJUNGAN TES KESEHATAN MANDIRI (ATKM). Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.
Text
Cover.pdf Download (1MB) |
|
Text
BAB I.pdf Download (1MB) |
|
Text
BAB II.pdf Restricted to Repository staff only Download (4MB) | Request a copy |
|
Text
BAB III.pdf Restricted to Repository staff only Download (746kB) | Request a copy |
|
Text
BAB IV.pdf Restricted to Registered users only Download (3MB) | Request a copy |
|
Text
BAB V.pdf Restricted to Repository staff only Download (186kB) | Request a copy |
|
Text
Daftar Pustaka.pdf Download (193kB) |
|
Text
Lampiran.pdf Restricted to Repository staff only Download (343kB) | Request a copy |
Abstract
Tensimeter adalah alat yang digunakan untuk mengukur tekanan darah seseorang melalui aktivitas pemompaan jantung yang kemudian diperoleh nilai sistolik dan diastolik. Tekanan darah yang tidak terkontrol dapat mengakibatkan kerusakan yang serius pada jantung dan pembuluh darah, sehingga dapat mengakibatkan kematian. Hal tersebut dapat di minimalisir dengan melakukan pengukuran tekanan darah secara teratur. Penelitian ini bertujuan untuk mengembangkan prototipe alat ukur tekanan darah digital serta sistem klasifikasi tekanan darah. Pengembangan prototipe dilakukan dengan membandingkan dan menganalisis tiga buah sensor tekanan yaitu sensor MPX2050GP, MPX5050GP, dan MPX2100GP untuk menentukan sensor yang akan digunakan. Selain itu, sistem klasifikasi dikembangkan untuk mendeteksi kondisi kesehatan berdasarkan data yang diperoleh. Hasil penelitian menunjukkan bahwa sensor MPX5050GP menjadi sensor yang optimal jika untuk diaplikasikan pada tensimeter digital, karena memiliki keseimbangan yang baik antara nilai sensitivitas sebesar 0,0121 V/mmHg dan tingkat akurasi sensor sebesar 98,33%. Hasil sensitivitas kedua sensor lainnya yaitu sensor MPX2050GP memiliki nilai sensitivitas 0,0073 V/mmHg dengan tingkat akurasi 98,23% dan sensor MPX2100GP memiliki nilai sensitivitas sebesar 0,0092 V/mmHg dan tingkat akurasi sebesar 99,81%. Pengujian prototipe tekanan darah menunjukkan nilai rata-rata kesalahan relatif untuk tekanan darah sistolik sebesar 10,31% dan tekanan diastolik sebesar 7,79%. Berdasarkan pengujian tersebut dapat disimpulkan bahwa prototipe tensimeter digital mampu mengukur tekanan darah dengan akurasi yang memadai yaitu untuk tekanan sistolik sebesar 89,69% dan tekanan diastolik sebesar 92,21%. Kata-kata kunci: Tensimeter digital, tekanan darah, sensor MPX2050GP, sensor MPX5050GP, dan sensor MPX2100GP. ***** A tensimeter is a tool used to measure a person's blood pressure through the pumping activity of the heart, producing systolic and diastolic values. Uncontrolled blood pressure can cause serious damage to the heart and blood vessels, potentially causing death. This risk can be minimized by regularly measuring blood pressure. This research aims to develop a prototype of a digital blood pressure measuring device and a blood pressure classification system. The prototype development involved comparing and analyzing three pressure sensors: MPX2050GP, MPX5050GP, and MPX2100GP, to determine the most suitable sensor. In addition, a classification system was developed to detect health conditions based on the data obtained. The research results show that the MPX5050GP sensor is the optimal choice for application in digital sphygmomanometers, because it offers a good balance between a sensitivity value of 0,0121 V/mmHg and a sensor accuracy level of 98,33%. The sensitivity results for the other two sensors are that the MPX2050GP sensor has a sensitivity value of 0,0073 V/mmHg with an accuracy level of 98,23%, and the MPX2100GP sensor has a sensitivity value of 0,0092 V/mmHg with an accuracy level of 99,81%. Testing of the prototype showed an average relative error rate for systolic blood pressure of 10,31% and diastolic blood pressure of 7,79%. Based on these tests, it can be concluded that the digital sphygmomanometer prototype is capable of measuring blood pressure with adequate accuracy, namely 89,69% for systolic pressure and 92,21% for diastolic pressure. Keywords: Digital sphygmomanometer, blood pressure, MPX2050GP sensor, MPX5050GP sensor, and MPX2100GP sensor.
Item Type: | Thesis (Sarjana) |
---|---|
Additional Information: | 1). Dr. Umiatin, M.Si. 2). Haris Suhendar, S.Si.,M.Sc. |
Subjects: | Sains > Sains, Ilmu Pengetahuan Alam Sains > Fisika Ilmu Kedokteran > Teknik, Prosedur,Perlengkapan Medis |
Divisions: | FMIPA > S1 Fisika |
Depositing User: | Users 24927 not found. |
Date Deposited: | 19 Aug 2024 00:57 |
Last Modified: | 19 Aug 2024 00:57 |
URI: | http://repository.unj.ac.id/id/eprint/48927 |
Actions (login required)
View Item |