PERANCANGAN PROTOTIPE GELANG CERDAS TERINTEGRASI OXIMETER DAN TELEMETRI BERBASIS MIKROKONTROLER

TASYA NAGARIA LAUT, . (2022) PERANCANGAN PROTOTIPE GELANG CERDAS TERINTEGRASI OXIMETER DAN TELEMETRI BERBASIS MIKROKONTROLER. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.

[img] Text
COVER.pdf

Download (689kB)
[img] Text
BAB 1.pdf

Download (194kB)
[img] Text
BAB 2.pdf
Restricted to Registered users only

Download (628kB)
[img] Text
BAB 3.pdf
Restricted to Registered users only

Download (468kB)
[img] Text
BAB 4.pdf
Restricted to Registered users only

Download (1MB)
[img] Text
BAB 5.pdf
Restricted to Registered users only

Download (124kB)
[img] Text
DAFTAR PUSTAKA.pdf

Download (193kB)
[img] Text
LAMPIRAN.pdf
Restricted to Registered users only

Download (1MB)

Abstract

Saturasi oksigen merupakan kadar hemoglobin dalam darah yang dapat mengikat oksigen. Saturasi oksigen penting untuk dimonitoring karena tanpa tercapainya kadar oksigen yang cukup, organ tubuh dan jaringan akan mengalami gangguan fungsi kerja dan dapat mengindikasikan adanya gangguan atau penyakit pada tubuh. Pada awalnya, pengukuran kadar saturasi oksigen menggunakan metode invasif dengan melukai jaringan tubuh, sehingga menimbulkan rasa sakit dan kemungkinan infeksi. Oksimetri nadi adalah metode non-invasif untuk memantau tingkat saturasi oksigen berdasarkan sifat optik dengan mengukur perbedaan panjang gelombang cahaya merah (660 nm) dan cahaya inframerah (910 nm). Pada penelitian ini telah dilakukan perancangan dan pengembangan smartband pulse oximetry menggunakan metode telemetri. Kompomem yang digunakan yaitu Sensor MAX30102, ESP32, push button, Blynk dan software Arduino IDE AVR. Data yang dikumpulkan pada tahap kalibrasi didasarkan pada sampel homogen sebanyak 10 orang yang memiliki usia dan jenis kelamin yang sama. Pengukuran untuk setiap orang diulang lima kali untuk membandingkan prototipe yang dirancang dengan pulse oximetry konvensional. Dari data karakteristik didapatkan akurasi detak jantung sebesar ±98,5% dan akurasi tingkat saturasi oksigen sebesar ±99,3%. Setelah kalibrasi, smartband ini secara efektif dapat mendeteksi detak jantung dan saturasi oksigen secara real time. Data hasil pengukuran akan ditampilkan pada aplikasi blynk dan blynk akan mengirimkan data tersebut ke email. ****************************************** Oxygen saturation is the level of hemoglobin in the blood that can bind oxygen. Oxygen saturation is important to monitor because, without achieving sufficient oxygen levels, the body's organs and tissues of the body will get impaired work function and may indicate a disorder or disease in the body. Initially, the measurement of oxygen saturation levels uses an invasive method by injuring body tissues, that causing pain and possible infection. Pulse oximetry is a non-invasive method for monitoring oxygen saturation levels based on optical properties by measuring the difference in wavelengths of red light (660 nm) and infrared light (910 nm). In this research, the design and development of smartband pulse oximetry has been carried out using optical methods. The components used are Sensor MAX30102, ESP32, push button, Blynk and Arduino IDE AVR software. The data collected at the calibration stage was based on a homogeneous sample of 10 people of the same age and gender. Measurements for each person were repeated five times to compare the designed prototipe with a commercial pulse oximeter. From the characteristic data, the heart rate accuracy is ±98.5% and the oxygen saturation level accuracy is ±99.3%. After calibration, this smartband can effectively detect heart rate and oxygen saturation in real time. The measurement data will be displayed on the blynk application and blynk will send the data to an email.

Item Type: Thesis (Sarjana)
Subjects: Sains > Fisika
Divisions: FMIPA > S1 Fisika
Depositing User: PKL .
Date Deposited: 19 Nov 2024 07:01
Last Modified: 19 Nov 2024 07:01
URI: http://repository.unj.ac.id/id/eprint/52156

Actions (login required)

View Item View Item