EFEKTIVITAS PENCAHAYAAN PADA RUANG BACA DAN RUANG PERKULIAHAN DI GEDUNG BUNG HATTA PROGRAM PASCASARJANA UNJ MENGGUNAKAN SOFTWARE DIALUX EVO 8.2

EKA MARDIANA, . (2020) EFEKTIVITAS PENCAHAYAAN PADA RUANG BACA DAN RUANG PERKULIAHAN DI GEDUNG BUNG HATTA PROGRAM PASCASARJANA UNJ MENGGUNAKAN SOFTWARE DIALUX EVO 8.2. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.

[img] Text
COVER.pdf

Download (1MB)
[img] Text
BAB I.pdf

Download (197kB)
[img] Text
BAB II.pdf
Restricted to Registered users only

Download (1MB) | Request a copy
[img] Text
BAB III.pdf
Restricted to Registered users only

Download (202kB) | Request a copy
[img] Text
BAB IV.pdf
Restricted to Registered users only

Download (10MB) | Request a copy
[img] Text
BAB V.pdf

Download (131kB)
[img] Text
DAFTAR PUSTAKA.pdf

Download (125kB)
[img] Text
LAMPIRAN.pdf

Download (1MB)

Abstract

Eka Mardiana, EFEKTIVITAS PENCAHAYAAN PADA RUANG BACA DAN RUANG PERKULIAHAN GEDUNG BUNG HATTA PROGRAM PASCASARJANA UNJ MENGGUNAKAN SOFTWARE DIALUX EVO 8.2. Dosen Pembimbing : Massus Subekti, S.Pd., M.T dan Imam Arif Raharjo, S.Pd., M.T Penelitian ini bertujuan untuk menghasilkan kuat penerangan yang sesuai pada ruang baca dan ruang perkuliahan. Karena terkadang dalam pembangunan sebuah gedung, masih banyak beberapa teknisi yang belum mengikuti aturan yang telah ditetapkan untuk penerangan yang sesuai pada ruang baca dan ruang perkuliahan. Akibat dari kelalaian tersebut dapat menimbulkan ketidaknyamanan bagi pengguna gedung, diantaranya seperti membuat mata lelah dan mengakibatkan kurangnya fokus seseorang dalam melakukan pekerjaan. Pada penelitian ini menggunakan pendekatan kuantitatif dengan metode deskriptif rekayasa Teknik dengan memanfaatkan tiga fase yaitu pengukuran manual, perhitungan manual dan simulasi Dialux Evo 8.2. Pengukuran manual menggunakan Luxmeter sebagai alat ukur untuk mendapatkan nilai kuat penerangan yang terukur pada ruang baca dan ruang perkuliahan berdasarkan Standar. Perhitungan manual menggunakan cara perhitungan menurut SNI. Simulasi menggunakan Software Dialux Evo 8.2 untuk mengoptimalkan nilai kuat penerangan yang seharusnya digunakan pada ruang baca dan ruang perkuliahan. Hasil penelitian menunjukkan bahwa nilai kuat penerangan yang dihasilkan pada ruang baca dan ruang perkuliahan masih belum memenuhi standar yang ditentukan. Peneliti melakukan 3 skenario desain perbaikan. Desain perbaikan skenario pertama pada ruang baca dan ruang perkuliahan diperoleh rata-rata presentase optimalisasi 72% dan 57%, pada skenario kedua diperoleh presentase optimalisasi 20% s/d 88%, pada skenario ketiga titik lampu ditambah, merubah lampu dan merubah karakter dinding diperoleh presentase optimalisasi sebesar 23% s/d 89%. Maka dapat disimpulkan bahwa skenario dua yang dilakukan untuk pengoptimalisasian didapatkan beberapa hasil kuat penerangan yang sesuai dengan standar yang telah ditetapkan pada ruang baca dan ruang perkuliahan dan nilai simpangan yang dihasilkan antara ruangan yang tidak terkena cahaya matahari dan ruangan yang terkena cahaya matahari memiliki simpangan yang tidak jauh. Kata Kunci: Efektivitas, Pencahayaan, Pengukuran, Perhitungan, Simulasi Dialux Evo 8.2 Eka Mardiana, Effectiveness of Lighting in Reading Rooms and Lecture Building UNJ Postgraduate Program Using Dialux Evo Software 8.2. Supervisor : Massus Subekti, S.Pd., M.T dan Imam Arif Raharjo, S.Pd., M.T This research aims to produce of illumination the appropriate lighting in the reading room and lecture room. Because sometimes in the construction of a building, there are still many techicians who have not followed the rules that have been set for appropriate illumination lighting in the reading room and lecture rooms. As result of negligence can cause discomfort for building users, including such as making eyes tired and resulting in a lack of focus on someone doing work. In this research using a quantitative approach with a descriptive engineering method engineering by utilizing three phases i.e manual measurement, manual calculations and simulated of Dialux Evo 8.2. The manual measurement uses Luxmeter as a measurement to get the value of the measured illumination in the reading room and lecture rooms based on the Standar. The manual calculation uses the calculation method according to SNI. The simulation uses Dialux Evo 8.2 software to optimize the value of the lighting which should be used in the reading room and lecture rooms. The results showed that illumination values were produced in the reading room and the lecture rooms still did not meet the specified Standars. Research do 3 design scenario improvements. The first scenario in the reading room and the lecture room was obtained average optimization percentage of 72% and 57% in the second scenario obtained the optimization percentage 20% s/d 88%, in the third scenario of the light point added, changing the lamp and changing the wall character obtained an optimization percentage of 23% s/d 89%. It can be concluded that the scenario of two is done to Linux obtained some illumination results that conform to the Standars set in the reading room and the lecture room and the value of the deviation generated between the room that is not exposed to sunlight and the room that is exposed the sunlight has a nearby deviation. Keywords: Effectiveness, Lighting, Measurement, Calculation, Dialux Evo simulation 8.2.

Item Type: Thesis (Sarjana)
Additional Information: 1). Massus Subekti, S.Pd., M.T 2). Imam Arif R, S.Pd., M.T
Subjects: Teknologi dan Ilmu Terapan > Konstruksi Bangunan
Teknologi dan Ilmu Terapan > Teknik Elektronika
Divisions: FT > S1 Pendidikan Teknik Elektro
Depositing User: Users 1818 not found.
Date Deposited: 05 Mar 2020 12:02
Last Modified: 05 Mar 2020 12:02
URI: http://repository.unj.ac.id/id/eprint/5246

Actions (login required)

View Item View Item