KAJIAN KENYAMANAN TERMAL DAN KENYAMANAN VISUAL BERDASARKAN STANDAR PADA RUANG KULIAH DI PRODI PENDIDIKAN TEKNIK BANGUNAN UNIVERSITAS NEGERI JAKARTA

YONENGSIH, . (2024) KAJIAN KENYAMANAN TERMAL DAN KENYAMANAN VISUAL BERDASARKAN STANDAR PADA RUANG KULIAH DI PRODI PENDIDIKAN TEKNIK BANGUNAN UNIVERSITAS NEGERI JAKARTA. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.

[img] Text
COVER_YONENGSIH 1503618014_.pdf

Download (981kB)
[img] Text
BAB 1_YONENGSIH 1503618014.pdf

Download (362kB)
[img] Text
BAB II_YONENGSIH 1503618014.pdf
Restricted to Registered users only

Download (566kB) | Request a copy
[img] Text
BAB III_YONENGSIH 1503618014.pdf
Restricted to Registered users only

Download (341kB) | Request a copy
[img] Text
BAB IV_YONENGSIH 1503618014.pdf
Restricted to Registered users only

Download (619kB) | Request a copy
[img] Text
BAB V_YONENGSIH 1503618014.pdf
Restricted to Registered users only

Download (195kB) | Request a copy
[img] Text
DAFTAR PUSTAKA_YONENGSIH 1503618014.pdf

Download (199kB)
[img] Text
LAMPIRAN DAN RIWAYAT HIDUP.pdf
Restricted to Registered users only

Download (3MB) | Request a copy

Abstract

Gedung L Fakultas Teknik Universitas Negeri Jakarta merupakan salah satu gedung yang biasa digunakan sebagai ruang pembelajaran teori dan praktek bagi mahasiswa prodi Pendidikan Teknik Bangunan. Maka dari itu diperlukan kajian untuk mengetahui apakah ruangan-ruangan yang terdapat prodi Pendidikan Teknik Bangunan sudah memenuhi standar dan aspek-aspek kenyamanan, serta mencari upaya yang perlu dilakukan untuk menciptakan kenyamanan berdasarkan standar dan aspek-aspek kenyamanan. Dalam penelitian ini aspek kenyamanan yang diteliti adalah kenyamanan termal dan kenyamanan visual. Penelitian ini menggunakan metode penelitian kualitatif, dan teknik pengumpulan data menggunakan teknik observasi dan wawancara, kemudian dianalisis secara deskriptif untuk mengetahui ketercapaian aspek kenyamanan pada ruangan-ruangan di gedung prodi Pendidikan Teknik Bangunan Universitas Negeri Jakarta, alat yang digunukan pada penelitian ini adalah lux meter yang digunakan mengukur pencahayaan pada ruang kuliah dan termometer digunakan untuk mengukur suhu udara, penelitian ini dimulai pada pukul 08.00 WIB sampai pukul 16.00 WIB. Hasil yang diperoleh dari penelitian ini berdasarkan SNI 03 – 6575 – 2001 kenyamanan termal termasuk dalam kategori hangat nyaman pada ruangan L3 – 201 dan L4 – 201 dengan rata-rata suhu 25,90 C – 26,70 C sementara untuk ruang L5 – 300 dalam kategori nyaman optimal yaitu dengan suhu rata-rata 24,80 C. Kemudian kenyamanan visual belum sesuai dengan standar yang telah ditentukan dalam SNI 03 – 6572 – 2001, dimana standar yang ditetapkan untuk ruangan kelas adalah 250 lux, sementara ruangan L3 – 201 memiliki pencahayaan rata-rata 230 lux, L4 – 201 memiliki pencahayaan rata-rata 151 lux, dan L5 – 300 memiliki pencahayaan rata-rata 211 lux. ***** Building L of the Faculty of Engineering at the State University of Jakarta is one of the buildings commonly used as a space for theoretical and practical learning for students of the Building Engineering Education program. Therefore, a study is needed to determine whether the rooms in the Building Engineering Education program meet the standards and aspects of comfort, and to identify the efforts that need to be made to create comfort based on these standards and aspects. In this study, the aspects of comfort being examined are thermal comfort and visual comfort. This research uses qualitative research methods, and data collection techniques using observation and interviews, then analyzed descriptively to determine the achievement of comfort aspects in the rooms of the Building Engineering Education program building at the State University of Jakarta. The tools used in this research are a lux meter to measure lighting in classrooms and a thermometer to measure air temperature. This research was conducted from 08:00 AM to 04:00 PM. The results obtained from this study based on SNI 03 – 6575 – 2001 indicate that thermal comfort falls into the warm comfortable category in rooms L3 – 201 and L4 – 201 with an average temperature of 25.90 C – 26.70 C, while room L5 – 300 falls into the optimal comfortable category with an average temperature of 24.80 C. Then, visual comfort does not yet meet the standards set in SNI 03 – 6572 – 2001, where the standard for classroom lighting is 250 lux, while room L3 – 201 has an average lighting of 230 lux, L4 – 201 has an average lighting of 151 lux, and L5 – 300 has an average lighting of 211 lux.

Item Type: Thesis (Sarjana)
Additional Information: 1). Drs. Arris Maulana, M.T. ; 2). Adhi Purnomo, M.T.
Subjects: Geografi, Antropologi > Ilmu Lingkungan
Teknologi dan Ilmu Terapan > Teknik Lingkungan, Teknik Sanitasi