M IRFAN MARTA SAPUTRA, . (2020) PENGUJIAN ALAT PRESSURE REDUCING STATION UNTUK PENURUNAN TEKANAN GAS COMPRESSED NATURAL GAS DARI TEKANAN 200 BAR KE 2 BAR. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.
Text
01. COVER.pdf Download (1MB) |
|
Text
02. BAB 1.pdf Download (238kB) |
|
Text
03. BAB 2.pdf Download (426kB) |
|
Text
04. BAB 3.pdf Download (736kB) |
|
Text
05. BAB 4.pdf Download (1MB) |
|
Text
06. BAB 5.pdf Download (141kB) |
|
Text
07. DAFTAR PUSTAKA.pdf Download (254kB) |
|
Text
08. Lampiran Dan Riwayat Hidup.pdf Download (805kB) |
Abstract
ABSTRAK M Irfan Marta Saputra, Pengujian alat Pressure Reducing Station untuk penurunan tekanan gas Compressed Natural Gas dari tekanan 200 bar ke 2 bar Penelitian ini bertujuan untuk mengetahui hasil uji alat pressure reducing station untuk penurunan tekanan gas compressed natural gas dari tekanan 200 bar ke 2 bar. Manfaat dari penelitian ini untuk mengetahui spesifikasi alat pressure reducing station yang akan di pasarkan ke dunia industri. Membahas tentang proses pengujian alat pressure reducing station, yang menguji meliputi temperatur maksimal air, gas didalam tubing sebelum dan sesudah melewati heat exchanger, temperature gas didalam header penampung, temperature akhir gas setelah keluar regulator, menentukan debit gas yang keluar selama 1 menit dan tinggi api. Pengujian temperatur menggunakan alat thermocouple yang disambungkan dengan Arduino Uno. Hasil dari penelitian diperoleh spesifikasi alat pressure reducing station, sebagai berikut : Diketahui bahwa semakin besar bukaan trhottle maka laju aliran volume semakin besar naik secara linear. Hal ini akan menunjukan kalor yang harus dibuang selama expansi semakin besar, tinggi api juga dipengaruhi oleh bukaan throttle, sehingga semakin besar bukaan throttle maka semakin tinggi api yang dihasilkan. ABSTRACT M Irfan Marta Saputra, Testing tool Pressure Reducing Station for gas pressure drop Compressed Natural Gas from pressure 200 bar to 2 bar The study aims to determine the test result of the pressure reducing station for the compressed natural gas gas pressure drop from 200 bar pressure to 2 bars. Benefit from this research to know the specifications of the pressure reducing station tool that will be in market to the world of industry. Discussing the testing process of the pressure reducing station tool, which tests include the maximum temperature of water, the gas in the tubing before and after passing the heat exchanger, the gas temperature in the container header, the gas end temperature after exiting Gas discharge for 1 minute and high fire. Temperature testing using the calibrated thermocouple tool with Arduino Uno. Results of the study obtained specification of the pressure Reducing station tool, as follows: It is known that the greater the trhottle opening the greater the volume flow rate rises linearly. This will indicate the heat that must be discharged during expansion is greater, the height of the fire is also affected by the throttle opening, so the greater the throttle opening the higher the fire produced.
Item Type: | Thesis (Sarjana) |
---|---|
Additional Information: | 1).Pratoimo Setyadi, S.T.,M.T. 2).Ir.Nugroho Gama yoga, M.T. |
Subjects: | Teknologi dan Ilmu Terapan > Teknologi (umum) |
Divisions: | FT > S1 Pendidikan Teknik Mesin |
Depositing User: | Users 2049 not found. |
Date Deposited: | 10 Mar 2020 12:47 |
Last Modified: | 10 Mar 2020 12:47 |
URI: | http://repository.unj.ac.id/id/eprint/5590 |
Actions (login required)
View Item |