STUDI EKSPERIMMENTAL KINERJA PIPA KALOR BERDENYUT TERTUTUP DENGAN VARIASI KEMIRINGAN DAN FLUIDA KERJA

RANGGA BAGUS SANTOSA, . (2026) STUDI EKSPERIMMENTAL KINERJA PIPA KALOR BERDENYUT TERTUTUP DENGAN VARIASI KEMIRINGAN DAN FLUIDA KERJA. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.

[img] Text
COVER.pdf

Download (1MB)
[img] Text
BAB 1.pdf

Download (291kB)
[img] Text
BAB 2.pdf
Restricted to Registered users only

Download (796kB) | Request a copy
[img] Text
BAB 3.pdf
Restricted to Registered users only

Download (965kB) | Request a copy
[img] Text
BAB 4.pdf
Restricted to Registered users only

Download (1MB) | Request a copy
[img] Text
BAB 5.pdf
Restricted to Registered users only

Download (205kB) | Request a copy
[img] Text
DAFTAR PUSTAKA.pdf

Download (230kB)
[img] Text
LAMPIRAN.pdf
Restricted to Registered users only

Download (717kB) | Request a copy

Abstract

Penelitian ini mengkaji pengaruh sudut kemiringan dan jenis fluida kerja terhadap kinerja Close Loop Pulsating Heat Pipe (CLPHP) menggunakan pipa tembaga berdiameter dalam 2 mm dengan 5 lekukan dan filling ratio 65%. Variasi meliputi sudut 0°, 30°, 45°, 60°, 90° dengan fluida air distilasi dan etanol, serta input daya 10W50W. Parameter yang dianalisis adalah resistensi termal (Rth) dan laju perpindahan panas (Qout). Hasil menunjukkan bahwa sudut kemiringan sangat mempengaruhi kinerja CLPHP. Air distilasi mencapai Rth terendah 0,24°C/W pada 60° dan Qout 47W, sedangkan etanol mencapai Rth 0,60°C/W pada 60° dan Qout 49W pada 45°. Sudut 0° memberikan kinerja paling rendah. Etanol lebih efektif pada daya rendah–menengah karena titik didihnya yang rendah, sementara air distilasi optimal pada daya tinggi berkat kalor laten besar. Secara keseluruhan, air distilasi paling sesuai untuk sudut 60°–90° pada daya tinggi, sedangkan etanol optimal pada sudut 45° untuk daya 10–30 W. ***** This study analyzes the influence of inclination angle and working fluid type on the performance of a Closed Loop Pulsating Heat Pipe (CLPHP). The experimental setup uses a 2 mm inner diameter copper pipe with five turns and a 65% filling ratio. Variations include inclination angles of 0°, 30°, 45°, 60°, and 90°, working fluids (distilled water and ethanol), and heat input ranging from 10 W to 50 W. The evaluated parameters are thermal resistance (Rth) and heat transfer rate (Qout). Results show that inclination angle significantly affects CLPHP performance. Distilled water achieves the lowest Rth of 0.24°C/W at 60° and a maximum Qout of 47W, while ethanol records a minimum Rth of 0.60°C/W at 60° and a maximum Qout of 49W at 45°, both at 50W input. Performance decreases sharply at 0°. Ethanol performs better at low to medium heat input (10–30 W) due to its low boiling point, whereas distilled water is optimal at higher heat input (40-50W) because of its high latent heat. Overall, distilled water is recommended for inclination angles of 60°–90° under high heat input, while ethanol is most effective at 45° for applications requiring 10–30W.

Item Type: Thesis (Sarjana)
Additional Information: 1). Dr. Eng. I Wayan Sugita, M.T. ; 2). Dr. Ir. Ragil Sukarno, M.T., IPM.
Subjects: Teknologi dan Ilmu Terapan > Teknik Mesin, Mekanika Teknik
Divisions: FT > S1 Teknik Mesin
Depositing User: Users 32708 not found.
Date Deposited: 30 Jan 2026 02:50
Last Modified: 30 Jan 2026 02:50
URI: http://repository.unj.ac.id/id/eprint/64267