Abstract
Penelitian ini bertujuan untuk mengidentifikasi peluang-peluang penghematan energi di gedung Menara BTN, Jakarta Pusat, serta merekomendasikan langkah-langkah penghematan energi yang dapat ditindak lanjuti oleh pengelola gedung Menara BTN tersebut dan meningkatkan efisiensi penggunaan energi di gedung bangunan pemerintahan yang berbasis audit energi. Penelitian ini menggunakan metode deskriptif. Langkah yang pertama dilakukan adalah dengan mengumpulkan data sekunder berupa rekening listrik Gedung Menara BTN tahun 2014, kemudian dari data tersebut dihitung nilai Intensitas Konsumsi Energi (IKE), setelah itu dilakukan pengukuran parameter kelistrikan. Paremeter kelistrikan yang diukur antara lain; fluktuasi tegangan, ketidakseimbangan tegangan dan arus, harmonisa tegangan dan arus, dan faktor daya. Hasil pengukuran parameter kelistrikan tersebut kemudian dibandingkan dengan standar yang berlaku, setelah itu dilakukan analisis mitigasi pada parameter kelistrikan yang tidak sesuai standar, serta perbaikan parameter kelistrikan yang sudah sesuai standar namun masih dapat dioptimalkan. Dari analisis mitigasi dapat dihitung efisiensi penggunaan energi listrik dengan membandingkan pada nilai Intensitas Konsumsi Energi (IKE) sebelumnya. Dari hasil pengukuran ditemukan bahwa harmonisa arus pada gedung tersebut tidak sesuai standar. Nilai faktor daya pada gedung tersebut sudah sesuai standar pemerintah namun masih mungkin untuk dioptimalkan. Dari langkah mitigasi pada harmonisa arus dan pengoptimalan nilai faktor daya ditemukan peluang penghematan penggunaan energi dengan presentase efisiensi energi sebesar 11,8%. *This study aims to identify opportunities for energy saving in BTN Tower building, Central Jakarta, and recommend energy saving measures that can be followed up by management of BTN Tower building and improve the efficiency of energy use in government building based energy audit. This research uses descriptive method. The first step to do is to collect secondary data in the form of BTN Tower Building electricity bill in 2014, then from the data can be calculated Energy Consumption Intensity (IKE) value , after that measuring electrical parameter. Electrical parameter measured, among others; voltage fluctuation, voltage and current unbalance, harmonic voltage and current, and power factor. Electrical parameter measurement results are then compared with the applicable standard, after it carried out the analysis of mitigation on electrical parameters which are not according to the standard, as well as the improvement of the electrical parameter that have been standardized but can still be optimized. From the analysis of mitigation can be calculated efficiency of electrical energy use by comparing the value of the Energy Consumption Intensity (IKE) previously. From the measurement results found that the harmonic current at the building does not meet standard. The value of the power factor in the building is in compliance with government standard, but it is still possible to be optimized. From the step of mitigation in harmonic currents and power factor optimization value are found saving opportunities the use of energy with energy efficiency percentage is 11.8 %.
Item Type: | Thesis (Sarjana) |
---|---|
Additional Information: | 1). Dr. Suyitno, M.Pd ; 2). Imam Arif Raharjo, S.Pd., MT |
Subjects: | Teknologi dan Ilmu Terapan > Teknik Energi > Energi Listrik |
Divisions: | FT > S1 Pendidikan Teknik Elektro |
Depositing User: | Users 8922 not found. |
Date Deposited: | 20 May 2022 03:14 |
Last Modified: | 20 May 2022 03:14 |
URI: | http://repository.unj.ac.id/id/eprint/28461 |
Actions (login required)
View Item |