ASEP SOEPRIANTO, . (2022) PENGARUH NILAI SUHU DAN WAKTU PEMANASAN PADA KANDUNGAN NILAI KADAR AIR TERHADAP NILAI TEGANGAN TEMBUS MINYAK TRANSFORMATOR DI PT ELSEWEDY ELECTRIC INDONESIA CILEUNGSI. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.
Text
COVER.pdf Download (2MB) |
|
Text
BAB I.pdf Download (421kB) |
|
Text
BAB 2.pdf Restricted to Registered users only Download (1MB) | Request a copy |
|
Text
BAB 3.pdf Restricted to Registered users only Download (884kB) | Request a copy |
|
Text
BAB 4.pdf Restricted to Registered users only Download (909kB) | Request a copy |
|
Text
BAB 5.pdf Restricted to Registered users only Download (408kB) | Request a copy |
|
Text
DAFTAR PUSTAKA.pdf Download (219kB) |
|
Text
Lampiran.pdf Restricted to Registered users only Download (1MB) | Request a copy |
Abstract
Tujuan dari penelitian ini adalah untuk mengetahui apakah ada atau tidaknya pengaruh nilai suhu, nilai kadar air dan waktu pemanasan minyak transformator terhadap nilai tegangan tembus pada minyak transformator ketika terjadi pemanasan pada minyak transformator sebesar 50℃, 60℃ dan 70℃. Metode yang digunakan adalah metode eksperimen. Subjek penelitian yang akan diteliti adalah minyak transformator Ergon Hyvolt dalam keadaan telah difiltrasi dan disimpah terlebih dahulu. Pada pengumpulan data, dilakukan pengambilan sampel minyak transformator kemudian dilakukan pemanasan pada minyak transformator pada suhu 50℃, 60℃ dan 70℃ dengan variasi waktu pemanasan 60 menit dan 120 menit pada setiap suhu pemanasan. Hasil minyak yang sudah dipanaskan akan dilakukan pengecekan nilai kadar air menggunakan Hand-held Oil Moisture Meter Titrino Coulumeter dan pengujian nilai tegangan tembus dengan alat Breakdown voltage Test Breakdown voltage Test Baur DTA 100 sebanyak 6 kali pada setiap sampel. Hasil pengujian sampel minyak transformator yang didapat lalu dilakukan analisis hubungan antara masing-masing variabel pada masing-masing sampel minyak transformator. Dari hasil pengujian diperoleh data waktu pemanasan 60 menit dengan suhu 50℃, 60℃ dan 70℃ memiliki nilai kadar air 10ppm, 9ppm, 7ppm dan nilai tegangan tembusnya adalah 72,8 kV, 74,2 kV, 85 kV. Sedangkan dengan waktu pemanasan 120 menit dengan suhu 50℃, 60℃ dan 70℃ memiliki nilai kadar air 10ppm, 8ppm, 6ppm dan nilai tegangan tembusnya adalah 73,5 kV, 76,9 kV, 85,4 Kv. Dari data yang didapat setelah melakukan pengujian menunjukkan bahwa terdapat pengaruh tinggi antara nilai suhu terhadap nilai tegangan tembus ketika minyak mengalami pemanasan. Pengaruhnya adalah ketika minyak mengalami kenaikan suhu maka nilai tegangan tembus akan ikut mengalami kenaikan. Hal ini disebabkan karena berkurangnya kadar air pada minyak saat dipanaskan. Pengaruh tinggi pun terjadi antara nilai kadar air terhadap nilai tegangan tembus. Pengaruhnya adalah semakin tinggi nilai kadar air maka nilai tegangan tembus akan mengalami penurunan. Hal ini disebabkan karena kenaikan nilai kadar air akan menurunkan kemampuan dielektrik minyak. Waktu pemanasan juga memiliki pengaruh terhadap nilai tegangan tembus minyak walapun dalam skala sangat rendah. Hal ini disebabkan karena karena unsur-unsur kelembaban atau gelembung air akan turut menguap seiring dengan peningkatan suhu pada minyak. ***** The purpose of this study was to determine whether or not there is an effect of temperature value, moisture content value and heating time of transformer oil on the breakdown voltage value of transformer oil when heating occurs in transformer oil of 50℃, 60℃ and 70℃ The method used is the experimental method. The research subject to be studied is Ergon Hyvolt transformer oil in a state that has been filtered and stored first. In data collection, transformer oil samples were taken and then the transformer oil was heated at temperatures of 50℃, 60℃ and 70℃ with variations in heating time of 60 minutes and 120 minutes at each heating temperature. The results of the heated oil will be checked for the water content value using the Hand-held Oil Moisture Meter Titrino Coulumeter and the breakdown voltage value will be tested with the Breakdown voltage Test Breakdown voltage Test DTA 100 tool 6 times for each sample. The test results of the transformer oil samples obtained were then analyzed for the relationship between each variable in each transformer oil sample. From the test results obtained data heating time of 60 minutes with temperatures of 50℃, 60℃ and 70℃ has a water content value of 10ppm, 9ppm, 7ppm and the breakdown voltage values are 72.8 kV, 74.2 kV, 85 kV. Meanwhile, with a heating time of 120 minutes with temperatures of 50℃, 60℃ and 70℃ the water content values are 10ppm, 8ppm, 6ppm and the breakdown voltage values are 73.5 kV, 76.9 kV, 85.4 Kv. From the data obtained after conducting the test, it shows that there is a high influence between the temperature value and the breakdown voltage value when the oil is heated. The effect is that when the oil temperature increases, the breakdown voltage value will also increase. This is due to the reduced water content of the oil when heated. A high influence also occurs between the value of the water content and the value of the breakdown voltage. The effect is that the higher the value of the water content, the value of the breakdown voltage will decrease. This is because the increase in the value of the water content will reduce the dielectric ability of the oil. Heating time also has an influence on the value of the breakdown voltage of the oil even though it is on a very low scale. This is because the elements of moisture or water bubbles will also evaporate along with the increase in temperature of the oil. Keywords: Transformer Oil, Temperature, Heating Time, Moisture Content
Item Type: | Thesis (Sarjana) |
---|---|
Subjects: | Teknologi dan Ilmu Terapan > Teknik Energi > Energi Listrik |
Divisions: | FT > S1 Pendidikan Teknik Elektro |
Depositing User: | Users 15539 not found. |
Date Deposited: | 01 Sep 2022 01:37 |
Last Modified: | 01 Sep 2022 01:37 |
URI: | http://repository.unj.ac.id/id/eprint/34018 |