ROY OKTAF FIYANTO, . (2024) RANCANG BANGUN ALAT PEMANTAU DETAK JANTUNG DAN SATURASI OKSIGEN DALAM DARAH MANUSIA PADA KONDISI TIDUR BERBASIS INTERNET OF THINGS. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.
Text
COVER.pdf Download (1MB) |
|
Text
BAB I.pdf Download (123kB) |
|
Text
BAB II.pdf Restricted to Registered users only Download (1MB) | Request a copy |
|
Text
BAB III.pdf Restricted to Registered users only Download (977kB) | Request a copy |
|
Text
BAB IV.pdf Restricted to Registered users only Download (1MB) | Request a copy |
|
Text
BAB V.pdf Restricted to Registered users only Download (100kB) | Request a copy |
|
Text
DAFTAR PUSTAKA.pdf Download (251kB) |
|
Text
LAMPIRAN.pdf Restricted to Registered users only Download (4MB) | Request a copy |
Abstract
Penelitian ini bertujuan untuk membuat alat pemantau detak jantung (BPM), saturasi oksigen (SpO2), dan elektrokardiogram (EKG) pada kondisi tidur berbasis IoT dan terhubung dengan Blynk serta Telegram. Alat ini memungkinkan pemantauan nilai BPM, SpO2, dan EKG melalui layar LCD pada alat atau secara jarak jauh melalui aplikasi Blynk dan Telegram sebagai media IoT. Penelitian ini menggunakan metode rekayasa teknik yang melibatkan perancangan, pembuatan alat, pengujian alat, pengumpulan data, dan analisis data. Subjek penelitian ini adalah BPM, SpO2, EKG, dan penerapan konsep IoT untuk memantau secara jarak jauh serta pemberian notifikasi secara Realtime. Teknik analisis data yang digunakan yaitu analisis deskriptif kuantitatif dengan teknik pengumpulan data yaitu observasi laboratorium. Kesimpulan hasil penelitian menunjukkan bahwa alat pemantau detak jantung dan saturasi oksigen dalam darah manusia berbasis IoT telah berhasil dibuat dengan menggunakan sensor MAX30102 dan AD8232 yang dihubungkan dengan NodeMCU ESP32, serta LCD untuk menampilkan hasil pengukuran. Pengukuran dilakukan pada dua belas responden dengan usia yang bervariasi. Pengukuran dilakukan dengan menempelkan ujung jari telunjuk tangan kiri pada sensor MAX3012 untuk mendapatkan data BPM dan SpO2, serta menempelkan elektroda dari sensor AD8232 untuk mendapatkan EKG dengan menggunakan metode sadapan Bipolar. Rentang nilai rata-rata pengukuran detak jantung berada pada 65-94 BPM. Rentang nilai rata-rata pengukuran saturasi oksigen berada pada 95%-98%. Alat ini memiliki nilai rata-rata kesalahan pengukuran (Error) untuk detak jantung (BPM) sebesar 1.63% dan untuk saturasi oksigen (SpO2) sebesar 2%. Alat ini juga berhasil menghubungkan media IoT Blynk untuk pemantauan jarak jauh secara Realtime dan aplikasi Telegram untuk media notifikasi jarak jauh. Kata Kunci: Detak Jantung, Elektrokardiogram, Internet of Things, Pemantauan, Saturasi Oksigen. ***** This research aims to create a heart rate monitoring device (BPM), oxygen saturation (SpO2), and electrocardiogram (ECG) in IoT-based sleep conditions and connected to Blynk and Telegram. This tool allows monitoring BPM, SpO2, and ECG values through the LCD screen on the tool or remotely through the Blynk and Telegram applications as IoT media. This research uses engineering methods that involve designing, making tools, testing tools, data collection, and data analysis. The subjects of this research are BPM, SpO2, ECG, and the application of IoT concepts to monitor remotely and provide real-time notifications. The data analysis technique used is quantitative descriptive analysis with data collection techniques, namely laboratory observation. The conclusion of the results shows that IoT-based monitoring of heart rate and oxygen saturation in human blood has been successfully made using MAX30102 and AD8232 sensors connected to NodeMCU ESP32, as well as LCD to display measurement results. Measurements were made on twelve respondents with varying ages. The measurement was carried out by attaching the tip of the index finger of the left hand to the MAX3012 sensor to obtain BPM and SpO2 data, and attaching electrodes from the AD8232 sensor to obtain an ECG using the Bipolar lead method. The range of average heart rate measurements is at 65-94 BPM. The average value range of oxygen saturation measurements is at 95%-98%. This tool has an average measurement error value (Error) for heart rate (BPM) of 1.63% and for oxygen saturation (SpO2) of 2%. The tool also successfully connects Blynk IoT media for Realtime remote monitoring and Telegram application for remote notification media. Keywords: Heart Rate, Electrocardiogram, Internet of things, Monitoring, Oxygen Saturation.
Item Type: | Thesis (Sarjana) |
---|---|
Additional Information: | 1). Mochammad Djaohar, M.Sc ; 2). Dr. Aris Sunawar, S.Pd., MT. |
Subjects: | Teknologi dan Ilmu Terapan > Teknik Energi > Energi Listrik Teknologi dan Ilmu Terapan > Teknik Elektronika Teknologi dan Ilmu Terapan > Teknik Energi Teknologi dan Ilmu Terapan > Teknik Komputer |
Divisions: | FT > S1 Pendidikan Teknik Elektro |
Depositing User: | Users 21543 not found. |
Date Deposited: | 01 Feb 2024 05:32 |
Last Modified: | 01 Feb 2024 05:32 |
URI: | http://repository.unj.ac.id/id/eprint/44065 |
Actions (login required)
View Item |