DOSMARIA MANULLANG, . (2022) IMMOBILISASI DITIZON DALAM MEMBRAN POLIVINIL KLORIDA UNTUK ANALISIS NIKEL. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.
Text
1. COVER.pdf Restricted to Registered users only Download (2MB) |
|
Text
2. BAB 1.pdf Restricted to Registered users only Download (838kB) |
|
Text
3. BAB 2.pdf Restricted to Registered users only Download (2MB) |
|
Text
4. BAB 3.pdf Restricted to Registered users only Download (1MB) |
|
Text
5. BAB 4.pdf Restricted to Registered users only Download (3MB) |
|
Text
6. BAB 5.pdf Restricted to Registered users only Download (295kB) |
|
Text
7. DAFTAR PUSTAKA.pdf Restricted to Registered users only Download (983kB) |
|
Text
8. LAMPIRAN.pdf Restricted to Registered users only Download (2MB) |
Abstract
Metode analisis yang sederhana, murah dan ramah lingkungan untuk menentukan Ni(II) dalam air minum telah dikembangkan, dengan immobilisasi ditizon (C13H12N4S) dalam matriks polivinil klorida (PVC) dan Dioktil ftalat sebagai pemlastis. Nikel merupakan salah satu logam yang bersifat toksik yang berbahaya bagi kesehatan manusia dan lingkungan. Percobaan ini dilakukan dengan tahapan pembuatan membran sensor yang kemudian dilanjutkan ke tahap karakterisasi membran sensor dengan menggunakan spektrofotometri UV-Vis, Spektrofotometri Serapan Atom, Karakterisasi dengan FTIR dan SEM. Serapan ion Ni(II) telah menyebabkan perubahan warna dari hijau menjadi merah kecoklatan dengan serapan maksimum pada yaitu 418 nm dan respon optimum membran sensor diperoleh pada pH 8,8. Ukuran membran sensor yang diajukan 1 cm x 2 cm dan volume sampel 2 mL dengan rentang konsentrasi 0-0,06 ppm. Hasil validasi metode analisis nikel dalam membran sensor memiliki linearitas metode sebesar R2 0,996 pada rentang 0-0,08 mg L-1. Absortivitas molar sebesar 4,144119 x 102 L mol-1 cm-1. Serta batas deteksi sebesar 0,00657 mg L-1 dan batas kuantitasi sebesar 0,019 mg L-1. Metode yang telah diaplikasikan untuk menentukan Ni(II) dalam sampel air minum setelah penambahan larutan standar dengan rekoveri 82,93 – 109,49% pada pengukuran spektrofotometer UV-Vis sedangkan dengan pengukuran spektrofotometeri serapan atom diperoleh rekoveri sebesar 104,11 - 107,96%. Nikel yang terkandung dalam air minum tidak melebihi batas pesyaratan kualitas air minum menurut PERMENKES RI Nomor: 907/MENKES/PER/VII/2010. ******************************************************** A simple analitical method, cheap and biological friendly to find Ni(II) in a drinking water was developed by dithizone immobilization in chloride polivinyl matrix (PVC) and dioctyl phthalate as plasticizer. Nickel is a metal that toxic and dangerous for human and environmental. The experiment was made by the step to make a membrane sensor which is next to the step characterization of membrane sensor with spectrophotometry UV-Vis, atomic absorption spectrophotometry (AAS), characterization with FTIR and SEM. The absorption of Ni(II) ion has caused the change of colour from green to brownish red with maximum absorption which in 418 nm and optimum respons of membrane sensor gaining on pH 8,8. The proposed membrane sensor size is 1 x 2 cm and the sample volume is 2 mL with a concentration range of 0 – 0.06 ppm. The method validation of analysis of nickel with membrane sensor have a linearity of the method with R2 0.996 in the range of 0-0.08 mg L-1. The molar absorptivity of 4.144119 x 102 L mol-1 cm-1. The value of limit of detection (LOD) of 0.00657 mg L-1 and quantitation limit (LOQ) value of 0.019 mg L-1. The method that had been applied for determine Ni(II) in a water sample after the addition of standard solution with recovery 82.93 – 109.49% in spectrophotometry UV-Vis while with atomic absorption spectophotometry measurments obtained recovery of 104.11 – 107.96%. The Nickel that contained in drinking water cannot exceeding the regulation of quality drinking water by PERMENKES RI No: 907/KEMENKES/PER/VII/2010.
Item Type: | Thesis (Sarjana) |
---|---|
Additional Information: | 1). Dr. Moersilah, M.Si.; 2). Elsa Vera Nanda, M.Si |
Subjects: | Sains > Kimia |
Divisions: | FMIPA > S1 Kimia |
Depositing User: | sawung yudo |
Date Deposited: | 01 Nov 2024 03:31 |
Last Modified: | 01 Nov 2024 03:31 |
URI: | http://repository.unj.ac.id/id/eprint/51878 |
Actions (login required)
View Item |