EKO PRASETYO, . (2014) ANALISA PEMETAAN SUHU MATERIALPADA GARDU DISTRIBUSI PT. PLN (PERSERO) AREA MARUNDA PADA PENYULANG TIUP. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.
Text
Lampiran Depan - Eko Prasetyo -5115096960.pdf Download (360kB) |
|
Text
BAB I - Eko Prasetyo - 5115096960.pdf Download (214kB) |
|
Text
BAB II - Eko Prasetyo - 5115096960.pdf Download (1MB) |
|
Text
BAB III - Eko Prasetyo - 5115096960.pdf Download (244kB) |
|
Text
BAB IV-Eko Prasetyo-5115096960.pdf Download (941kB) |
|
Text
BAB V - Eko Prasetyo - 5115096960.pdf Download (95kB) |
|
Text
Daftar Pustaka - Eko Prasetyo - 5115096960.pdf Download (90kB) |
Abstract
Penelitian ini bertujuan untuk mengurangi gangguan kelistrikan yang terjadi karena kerusakan material gardu akibat tingkat suhu yang tinggi serta mendapatkan data pemetaan suhu material pada sistem distribusi tenaga listrik di PT. PLN (Persero)Area Marundapada bulan Maret -April2014. Penelitian dilakukandengan metode observasi lapangandiawalidengan pengumpulan data-data serta teori-teori yang berhubungan dengan penelitian selanjutnya dilakukan pengukuran suhu material ke 9 gardu distribusi yang terdapat pada penyulang Tiup. Pengukuran dilakukan pada beberapa titik material gardu distribusi yaitu pada bushing transformator primer (U, V, W), bushing transformator sekunder (R, S, T dan N) serta PHB-TR (R, S dan T) dan pemetaan suhu dilakukan dengan cara membandingkan suhu material dengan suhu standar lapangan untuk untuk mendapatkan hasil presentase suhu material yang akan di masukan ke dalam perhitungan metode rating scale.Setelah dilakukan pengukuran suhu material pada gardu distribusi di PT. PLN (Persero) Area Marunda pada penyulang Tiup, yang memiliki tingkat suhu material gardu distribusi tinggi yang menyebabkan sering terjadinya gangguan kelistrikan. Gardu CK 77 yang memiliki tingkat rata-rata suhu tertinggi di beberapatitik material Bushingtransformatorprimer 83,36oC (Kurang Baik), Bushingtransformator sekundermencapai 95,4oC (Kurang Baik) danpada PHB-TR sebesar 111,13oC sedangkan GarduCK 57 yang memiliki tingkat suhu terendah pada titik material Bushingtransformatorprimer 38,23oC(Baik) Bushingtransformator sekundersebesar40,92oC (Cukup) dan pada Papan Hubung Bagi Tegangan Rendah (PHB-TR) sebesar 66,83oC (Kurang). Sehingga Kesimpulan dari penelitian ini menunjukan bahwa rata-rata suhu di beberapa titik material gardu distribusi CK 57 masih dalam katagori Baik. Namun rata-rata suhu di beberapa titik material pada gardu distribusi CK 77memiliki tingkat suhu Kurang Baik dengan presentase 97% pada material Bushing sekunder dengan rata-rata suhu material 95,4oC. *********** This study aims to reduce electrical interference that occurs due to material damage as a result of substation due to high temperatures and toobtain material temperature mapping data on the electricity distribution system in the PT. PLN (Persero) Marunda area in March -April 2014. The study was conducted by field observation method begins with the collection of data and theories related to the research conducted subsequent to 9 temperature measurements of material contained on the distribution substation feeders Blow. Measurements were taken at some point the material that is on bushing distribution substation transformer primary (U, V, W), secondary transformer bushing (R, S, T and N) and PHB-TR (R, S and T) and temperature mapping is done by comparing the temperature of the material with a standard temperature field for the temperature to get the percentage of material that will be input to the calculation method of rating scale. After the temperature measurement of materials at distribution substations in PT. PLN (Persero) in the feeder Blow Marunda area, which has a distribution substation high temperature materials that cause frequent occurrence of electrical interference. CK 77 substations which have an average rate highest temperature at some point the primary transformer Bushing material 83.36oC (Not Good), Bushing secondary transformer reaches 95.4 ° C (Not Good) and the PHB-TR for 111,13oC while Substation CK 57 which has a lowest temperature of the material at the point of primary transformer bushings 38,23oC (good) secondary transformer bushings for 40,92oC (Self) and the Connecting for Low Voltage Board (PHB-TR) of 66,83oC (Less). So the conclusion from this study showed that the average temperature of the material at some point CK 57 distribution substations still in the good category. However, the average temperature of the material at some point in the distribution substation CK 77 has a temperature level Less Neither the percentage of 97% in the secondary Bushing material with an average temperature 95,4oC material.
Item Type: | Thesis (Sarjana) |
---|---|
Additional Information: | 1). Massus Subekti, S.Pd., M.T. ; 2). Drs. Irzan Zakir, M.Pd. |
Subjects: | Teknologi dan Ilmu Terapan > Teknik Elektronika Teknologi dan Ilmu Terapan > Teknik Energi |
Divisions: | FT > S1 Pendidikan Teknik Elektro |
Depositing User: | Rima Safitri . |
Date Deposited: | 26 Mar 2021 04:23 |
Last Modified: | 26 Mar 2021 04:23 |
URI: | http://repository.unj.ac.id/id/eprint/15517 |
Actions (login required)
View Item |