ENDRIK, . (2022) ANALISIS PENGARUH LUAS PENAMPANG, KEDALAMAN DAN JENIS ELEKTRODA TERHADAP TAHANAN PENTANAHAN DI SMKN 56 JAKARTA. Sarjana thesis, UNIVERSITAS NEGERI JAKARTA.
Text
COVER.pdf Download (938kB) |
|
Text
BAB I.pdf Download (217kB) |
|
Text
BAB II.pdf Restricted to Registered users only Download (466kB) | Request a copy |
|
Text
BAB III.pdf Restricted to Registered users only Download (665kB) | Request a copy |
|
Text
BAB IV.pdf Restricted to Registered users only Download (1MB) | Request a copy |
|
Text
BAB V.pdf Restricted to Registered users only Download (208kB) | Request a copy |
|
Text
DAFTAR PUSTAKA.pdf Download (338kB) |
|
Text
LAMPIRAN.pdf Restricted to Registered users only Download (3MB) | Request a copy |
Abstract
Penelitian ini bertujuan untuk mengetahui pengaruh luas penampang, kedalaman, dan jenis elektroda terhadap nilai tahanan pentanahan.Selain itu juga untuk mengetahui titik ideal penanaman elektroda <5 ohm. Metode yang digunakan dalam penelitian ini adalah metode eksperimen. Data diambil berdasarkan elektroda batang dengan diameter 5mm:10mm:15mm:20mm pada kedalaman 50cm:100cm:150cm:200cm, elektoda plat luas penampang 25cm2:100cm2:225cm2:400cm2 pada kedalaman 25cm:50cm:75cm:100cm, kemudian data diperoleh dan dianalisis untuk mendapat kesimpulan.Hasil pengukuran penambahan diameter memiliki pengaruh rata-rata keseluruhan 0,2 ohm, penambahan kedalaman memiliki pengaruh rata-rata keseluruhan 1,8 ohm, titik ideal penanaman elektroda <5 ohm pada kedalaman >100 cm dengan diameter tetap.Selisih pengukuran dan perhitungan elektroda batang hampir sama, dengan selisih rata-rata 5,7%.Pengaruh penambahan kedalaman elektroda plat memiliki rata-rata keseluruhan 0,7 ohm,dan hasil penambahan luas penampang memiliki rata-rata keseluruhan 2,1 ohm. titik ideal penanaman elektroda <5 ohm pada kedalaman >50 cm dengan luas penampang >225cm2. Selisih pengukuran dan perhitungan rata-rata 93,0 % hal ini mengalami perbedaan karena pesepsi pengguanan jenis elektroda yang tidak maksimal tertekan berkontak dengan tanah. ***** This study aims to determine the effect of cross-sectional area, depth, and type of electrode on the value of grounding resistance. In addition, to determine the ideal point for implanting electrodes <5 ohms. The method used in this research is the experimental method. Data was taken based on rod electrodes with a diameter of 5mm:10mm:15mm:20mm at a depth of 50cm:100cm:150cm:200cm, an electrode plate with a cross-sectional area of 25cm2:100cm2:225cm2:400cm2 at a depth of 25cm:50cm:75cm:100cm, then the data was obtained and analyzed to get a conclusion. The measurement results of increasing the diameter have an overall average effect of 0.2 ohm, adding depth has an overall average effect of 1.8 ohm, the ideal point of implanting the electrode is <5 ohm at a depth of> 100 cm with a fixed diameter. Difference in measurements and the calculation of the rod electrode is almost the same, with an average difference of 5.7%. The effect of adding depth to the plate electrode has an overall average of 0.7 ohms, and the result of adding cross-sectional area has an overall average of 2.1 ohms. the ideal point for implanting electrodes is <5 ohms at a depth of >50 cm with a cross-sectional area of >225cm2. The difference in measurements and calculations averages 93.0%, this is a difference due to the perception of using an electrode type that is not maximally pressed against the ground. Keywords: Electrode Type, Electrode Depth, Electrode Cross-sectional Area, Grounding Resistance.
Item Type: | Thesis (Sarjana) |
---|---|
Additional Information: | 1). Massus Subekti, S.Pd., M.T. ; 2). Dr. Aris Sunawar, S.Pd., M.T. |
Subjects: | Teknologi dan Ilmu Terapan > Teknik Energi > Energi Listrik |
Divisions: | FT > S1 Pendidikan Teknik Elektro |
Depositing User: | Users 16831 not found. |
Date Deposited: | 20 Feb 2023 01:15 |
Last Modified: | 20 Feb 2023 01:15 |
URI: | http://repository.unj.ac.id/id/eprint/36902 |